Abstract: along with the continuous progress of society, the economy continues to grow, the people to the quality of life and the corresponding continuously improve, so give architectural development provided to the wider development space. As a modern residential construction can not lack of electrical installation project also constantly improving the quality of the installation, current primary task is effective to overcome the quality problems electrical engineering problems. With China's entry into since the reform and open policy, foreign have developed many more advanced technology and products, and these new technology and products have been constantly into China's construction market, which the country's electrical building industry faced with new challenges. However, with the development of electrical building, electrical installation engineering problems but no fundamental change, therefore, this article is building electrical installation common problems in the relevant analysis and discussion, for reference.
Keywords: building, electrical engineering, installation, common problem
中圖分類號(hào): TU855 文獻(xiàn)標(biāo)識(shí)碼:A 文章編號(hào):
由于我國(guó)國(guó)民經(jīng)濟(jì)不斷的增長(zhǎng),人們對(duì)待住宅的要求也是不斷提高。在現(xiàn)代住宅建設(shè)中電氣工程的安裝顯得尤為重要,它是隨著建筑行業(yè)的迅速興起而發(fā)展起來的。電氣安裝工程貫穿了整個(gè)建筑工程的施工過程和使用過程,因此,居民住宅建設(shè)質(zhì)量的好壞直接受到電氣工程質(zhì)量的影響。目前,我國(guó)正在飛速的發(fā)展,建筑行業(yè)也呈現(xiàn)出了迅猛發(fā)展的趨勢(shì),這就給電氣工程行業(yè)帶來了一定的發(fā)展空間,但是,發(fā)展的同時(shí)還是存在著一些問題值得我們?nèi)シ治龊脱芯?,以免影響到人們的生活質(zhì)量。
一、電氣安裝工程中的施工隊(duì)伍
有些工程不會(huì)按照建設(shè)的相關(guān)程序流程辦事,私自雇用一些資質(zhì)等級(jí)完全不符的施工單位和個(gè)人進(jìn)行施工。這些施工單位和施工人員在專業(yè)技術(shù)上沒有很高的水平,技術(shù)力量也相當(dāng)?shù)谋∪?,這就導(dǎo)致了電氣安裝工程最后達(dá)不到有關(guān)規(guī)定的標(biāo)準(zhǔn),出現(xiàn)了很多的質(zhì)量問題,嚴(yán)重影響著人們的生活。
二、電氣的相關(guān)材料和主要設(shè)備
導(dǎo)線電阻率高、熔點(diǎn)低、機(jī)械性能差、截面小于標(biāo)稱值、絕緣差、溫度系數(shù)大、溫度系數(shù)大、尺寸不夠數(shù)等;電纜耐壓低、絕緣電阻小、抗腐蝕性差、耐溫低。內(nèi)部接頭多、絕緣層與線芯嚴(yán)密性差;動(dòng)力、照明、插座箱外觀差,幾何尺寸達(dá)不到要求,鋼板、塑殼厚度不夠,影響箱體強(qiáng)度,耐腐蝕性達(dá)不到要求;開關(guān)、插座導(dǎo)電值與標(biāo)稱值不符,導(dǎo)電金屬片彈性不強(qiáng),接觸不好,易發(fā)熱,達(dá)不到安全要求,塑料產(chǎn)品阻燃低、耐溫、安全性能差等;燈具、光源粗制濫造,機(jī)械強(qiáng)度差,防銹防腐性能差,使用壽命短等;各種電線管壁薄,強(qiáng)度差,鍍鋅層質(zhì)量不符合要求,耐折性差等。這些主要設(shè)備和相關(guān)材料如果出現(xiàn)了問題,也會(huì)直接影響到最終工程的質(zhì)量。
三、 配電箱和接線盒
配電箱和接線盒的安裝標(biāo)準(zhǔn)是不一樣的,這類設(shè)備的安裝會(huì)出現(xiàn)以下問題:配電箱和接線盒的安裝標(biāo)高沒有形成一致,坐標(biāo)的偏移比較突出;配電箱和接線盒沒有整齊的開孔;配電箱和接線盒內(nèi)的贓物沒有徹底的清理干凈;管子口進(jìn)入配電箱和接線盒里的部分太多了;沒能有效的固定住,防銹防腐處理不是很到位等。這些問題也會(huì)直接影響到最終安裝是否能夠達(dá)標(biāo)。
四、電線管的敷設(shè)
薄壁管代替厚壁管,黑鐵管代替鍍鋅管,PVC 管代替金屬管;穿線管彎曲半徑太小,并出現(xiàn)彎癟、彎皺,嚴(yán)重時(shí)出現(xiàn)“死彎”。管子轉(zhuǎn)彎不按規(guī)定設(shè)過渡盒;金屬管口毛刺不處理,直接對(duì)口焊接,絲扣連接處和通過中間接線盒時(shí)不焊跨接鋼筋,或焊接長(zhǎng)度不夠,“點(diǎn)焊”和焊穿管子現(xiàn)象嚴(yán)重。鍍鋅管和薄壁管不用絲接,用焊接;鋼管不接地或接地不牢;管子埋墻、埋地深度不夠,預(yù)制板上敷管交叉太多,影響土建施工。現(xiàn)澆板內(nèi)敷管集中排成捆影響結(jié)構(gòu)安全;管子通過結(jié)構(gòu)伸縮縫及沉降縫不設(shè)過路箱,留下不安全的隱患;明、暗管進(jìn)箱進(jìn)盒不順直,擠成一捆,露頭長(zhǎng)度不合適,鋼管不套絲、PVC 管無鎖緊等。
五、防雷接地
在防雷接地極的測(cè)試點(diǎn)沒有詳細(xì)的說明;在設(shè)置防雷接地極電阻的測(cè)試點(diǎn)沒有達(dá)到相關(guān)的規(guī)定和要求。避雷帶采用的是最為普通的圓鋼進(jìn)行的敷設(shè),避雷帶之間以及引線下線都是采用的單面焊接或者是對(duì)面焊接方式,搭接的長(zhǎng)度也不符合要求,焊接口處出現(xiàn)嚴(yán)重的銹蝕現(xiàn)象;支架之間形成了太大的距離,帶形也發(fā)生了嚴(yán)重的變形脫落,彎角處以及引下角都是銳角,引下點(diǎn)之間形成了較大的間距;在建筑中的屋角沒有做好防雷接地的工作。
六、室外進(jìn)戶管預(yù)埋問題
用薄壁銅管代替了之前采用的厚壁銅管,室外進(jìn)戶預(yù)埋的深度也沒能按照規(guī)定的標(biāo)準(zhǔn)進(jìn)行,位置也發(fā)生了嚴(yán)重的偏差;在轉(zhuǎn)彎的地方采用電焊進(jìn)行燒彎,水平進(jìn)戶管網(wǎng)和上墻管采用電焊燒彎,最后的角度接近90度角;在地下室外墻和進(jìn)戶管處的防水問題沒有得到有效的解決,出現(xiàn)了嚴(yán)重的滲水現(xiàn)象,嚴(yán)重影響了最終安裝工程的質(zhì)量問題。
七、吊頂層
在吊頂層的施工過程中,配管的走向線路發(fā)生了偏移,走向也是很不規(guī)則的,形成了高低起伏的形狀。金屬的軟管也沒有做好相應(yīng)的跨接接地保護(hù)工作,沒安裝保護(hù)線;預(yù)留管的長(zhǎng)度沒有達(dá)到要求和規(guī)定,這樣就會(huì)導(dǎo)致導(dǎo)線露在外面;接線盒也沒有蓋板,相應(yīng)的防腐防銹工作也不符合規(guī)定;在設(shè)置吊支架的時(shí)候也沒能做好相應(yīng)的工作,設(shè)置不對(duì)稱,距離太大等,另外,有時(shí)候會(huì)直接把管子打在龍骨上用導(dǎo)線或者是鐵絲進(jìn)行相應(yīng)的固定,這是極為不合規(guī)定和要求的,嚴(yán)重影響了工程的質(zhì)量。
八、開關(guān)、插座、燈具
安裝偏位, 水平度、直線度偏差超過規(guī)定值; 日光燈用導(dǎo)線代替吊鏈, 引下線用硬導(dǎo)線, 軟導(dǎo)線不和吊鏈編叉直接接燈, 導(dǎo)線在日光燈罩上面敷設(shè); 吊扇鉤預(yù)埋與接線盒距離過大, 吊扇上罩遮不住接線盒孔洞,導(dǎo)線外露, 吊鉤不預(yù)埋, 吊扇固定在龍骨上;直接裝在頂板上的吸頂燈不裝圓木臺(tái)( 方木臺(tái)) 或木臺(tái)質(zhì)量差。裝在吊頂板上的吸頂燈不做固定框, 直接用自攻螺釘固定在頂板上及需要接地的燈具罩殼不接地。
九、總結(jié)
在整個(gè)電氣安裝工程中最為重要的核心部分就是建筑電氣安裝工程的質(zhì)量問題,只有不斷的提高施工人員的專業(yè)技術(shù)水平和素質(zhì),加強(qiáng)技術(shù)方面的培訓(xùn);提高相關(guān)管理部門的監(jiān)管和監(jiān)查責(zé)任就能夠有效的提高電氣工程安裝的質(zhì)量,最終確保整個(gè)工程的質(zhì)量,讓人們的生活不會(huì)受到任何建筑質(zhì)量的影響。
參考文獻(xiàn):
[1] 謝海峰. 電氣工程的質(zhì)量控制技術(shù)分析[J]. 中小企業(yè)管理與科技(上旬刊). 2008(07) .
[2] 賈志勇. 建筑智能化安全質(zhì)量分析[J]. China’s Foreign Trade. 2011(08) .
中圖分類號(hào):TU85 文獻(xiàn)標(biāo)識(shí)碼:A 文章編號(hào):1671-7597(2013)11-0000-00
我國(guó)的油田電氣工程建設(shè)還不是非常完善,有著各種各樣的問題等待著我們解決。這些常見的問題歸根結(jié)底是電氣工程建設(shè)設(shè)備上的問題。只有對(duì)這些設(shè)備進(jìn)行良好的管理,才能進(jìn)一步避免這些問題發(fā)生。所以說,對(duì)我國(guó)油田企業(yè)電氣設(shè)備的目前狀況分析,從而找出這些問題的解決方法,是十分必要的。
1 油田電氣工程建設(shè)設(shè)施當(dāng)前的情況
要是說到我國(guó)油田電氣工程建設(shè)設(shè)備的當(dāng)前情況,可以從兩個(gè)方面來說。一方面是有利的一方面,就是根據(jù)以往的一項(xiàng)調(diào)查顯示,在2000到2010的十年間,不論是出現(xiàn)故障的數(shù)量,還是出現(xiàn)故障所造成的經(jīng)濟(jì)損失,每年都在逐漸的下降,特別是重大和特大故障的出現(xiàn)頻率原則上來講已經(jīng)是沒有這些故障的發(fā)生了,這個(gè)現(xiàn)象側(cè)面的反應(yīng)出了油田公司中的管理人員對(duì)于安全的覺悟在進(jìn)一步的提升;珍愛生命,堅(jiān)持安全的工作和生活方法已經(jīng)變成了所有公司工作人員和施工人員的共同認(rèn)識(shí);實(shí)行油田公司安全生產(chǎn)的責(zé)任制度、著力進(jìn)行教育和培訓(xùn)等工作;對(duì)于安全作業(yè)的資金投入和潛在危險(xiǎn)的整治水平在進(jìn)一步提高。在管理方式上已經(jīng)逐漸的從經(jīng)驗(yàn)類型或者是事后處理類型轉(zhuǎn)化成為了預(yù)防類型的管理方法。
但是其中也存在著一些問題:1)油田電氣工程的電氣設(shè)施一般來說都是20世紀(jì)七十八十年代所購(gòu)買并且進(jìn)行運(yùn)行的。電氣設(shè)施使用的時(shí)間比較長(zhǎng),所以出現(xiàn)了比較嚴(yán)重的老化狀況,設(shè)施老化的現(xiàn)象所帶來的潛在危險(xiǎn)不能得到馬上的更正,所以在技術(shù)性能上面就不是特別安全。2)最近一段時(shí)間來說,伴隨著油田在深層次的開采,油田公司也越來越具有一定的規(guī)模,油田提供電能的網(wǎng)絡(luò)規(guī)模也在逐漸的擴(kuò)展著,同時(shí)具有一定的承載壓力。3)施工人員的素質(zhì)良莠不齊,而且多多少少都存在著“三個(gè)違反”的現(xiàn)象,而且有些施工單位的責(zé)任制度不能落實(shí)到個(gè)人,具有安全隱患。
2 油田電氣工程中常見的問題和原因
從一般角度來說,在油田開采過程中,提供電能的體系一定不能保證絕對(duì)的安全,原因就是這種安全問題總的來講都是和施工時(shí)候技術(shù)水準(zhǔn)相聯(lián)系的,所以這些故障是必能安全杜絕的,下面就對(duì)油田電氣工程建設(shè)中電氣設(shè)備的比較容易出現(xiàn)的故障進(jìn)行簡(jiǎn)單介紹。
2.1 電路或者設(shè)施絕緣層損壞而造成的漏電現(xiàn)象
當(dāng)電氣工程建設(shè)中的電路和設(shè)施的絕緣層遭到破壞從而造成接地故障的時(shí)候,關(guān)鍵值得是相線對(duì)于地面或者與地面有關(guān)系的導(dǎo)體之間的電路進(jìn)行短路,包含了相線和地面、pe線、配電線和使用電器的設(shè)施的金屬外殼、橋梁所架電線的槽、施工建筑零件、下水和上水還有暖氣管道、金屬墻體、水面相互間是否進(jìn)行短路等。每當(dāng)突然產(chǎn)生短路的時(shí)候連接地面的電線一旦故障,與這根電線有關(guān)的電氣裝置和管道的泄漏(能夠?qū)щ姷膶?dǎo)線)接地和設(shè)備外的可以導(dǎo)電的導(dǎo)線之間有著一定的故障電壓。這樣的電壓可以導(dǎo)致人的身體突然遭到點(diǎn)的擊打,也可能因?yàn)榈孛婢哂兄^大的電弧或者閃爍的火花所以可能導(dǎo)致火災(zāi)或者爆炸。
出現(xiàn)這種現(xiàn)象的原因有以下狀況:1)電壓比較低的配電體系的安裝元大多數(shù)不是電氣工程建設(shè)的專業(yè)人員,他們的專業(yè)技能良莠不齊,所以就很難保障質(zhì)量,體現(xiàn)在:比較潮濕或者在酸堿性特別強(qiáng)的外部環(huán)境里面,電線明放在外面,裝置沒有經(jīng)過保護(hù)就直接安裝等等。2)在安裝布置線路的時(shí)候,因?yàn)榈?、鉗、錘子等工具導(dǎo)致的絕緣體的損害沒有進(jìn)行馬上的處理。3)在安全的時(shí)候沒有遵循規(guī)范的操作,導(dǎo)線在連接的過程中質(zhì)量和絕緣體質(zhì)量不與實(shí)際的相求相符合。4)電氣工程線路或者裝置已經(jīng)使用了太多年已經(jīng)失去了功效,因?yàn)槌d負(fù)荷或者是使用年限太多而導(dǎo)致了絕緣層功能退化。5)一系列外部因素,比如說,混入了較多的水分、潮濕、酸堿腐蝕等等。
2.2 電壓比較低的變壓器在配電過程中常見的問題
電氣工程建設(shè)中的變壓器一般把高壓降低為低壓從而提供給電氣裝置所進(jìn)行工作。普遍來說把這種電氣體制的最后一級(jí)叫做低壓配電變壓器。
2.2.1 配電變壓器具有較壞的油質(zhì)或者是溫度驟然提升
在平常的工作過程中,變壓器當(dāng)中的油的功效就是冷卻和杜絕導(dǎo)電。每當(dāng)變壓器長(zhǎng)時(shí)間導(dǎo)致變壓器很熱或者變壓器里面進(jìn)入水的時(shí)候,吸收了潮濕的氣息,這樣就容易讓油的質(zhì)量變得很差。憑借油表面的觀察會(huì)觀察出油的顏色和往常不同,或者是加深或者是變成了黑色;取一些這樣油的樣本分析的時(shí)候能夠檢查出油里面包含的碳顆粒和水分還有ph數(shù)值減少,閃電比較低,不能有較高的絕緣強(qiáng)度,造成了纏繞在外面的導(dǎo)線和金屬外殼之間可能產(chǎn)生放電的效果,從而導(dǎo)致嚴(yán)重的故障。
出現(xiàn)這種情況的原因是,在變壓器正常工作的時(shí)候,油的問題驟然提升一般來說是變壓器里面熱度增加造成的。鐵芯產(chǎn)生著火現(xiàn)象,導(dǎo)線短路,里面的螺絲過松,冷卻設(shè)備故障,變壓器超負(fù)荷工作這些情況都可能導(dǎo)致溫度驟然提升。
2.2.2 變壓器發(fā)生火災(zāi)
一旦變壓器的里面發(fā)生了故障,但是沒有在第一時(shí)間進(jìn)行處理的話,就有可能有著火的現(xiàn)象發(fā)生,最后嚴(yán)重了就可能演變成為火災(zāi)。
在變壓器著火的時(shí)候,變壓器油箱里面的絕緣層就是發(fā)生燃燒。從而進(jìn)一步變成了氣體,這些氣體進(jìn)一步的結(jié)合,就導(dǎo)致了郵箱的爆炸,著火的絕緣油對(duì)著變壓器外面進(jìn)行噴流,這樣就導(dǎo)致了裝置的破壞和財(cái)產(chǎn)的損失。
出現(xiàn)這種情況的原因是,變壓器里面的導(dǎo)線里面或者外面發(fā)生了短路的現(xiàn)象,嚴(yán)重的符合超載、雷電擊打或者是外部環(huán)境的火的源頭移動(dòng)到了變壓器,都可能造成變壓器著火的現(xiàn)象發(fā)生。
3 避免油田電氣工程建設(shè)中的常見問題的方法
要避免這類問題的出現(xiàn),從而導(dǎo)致在施工中的工人生命和施工單位財(cái)產(chǎn)安全,就應(yīng)該防患于未然,在這些事故沒有發(fā)生之前進(jìn)行有效的預(yù)防。對(duì)于油田電氣工程建設(shè)設(shè)備的檢查方式有以下幾種。
3.1 對(duì)于出口短路故障方式的檢查
電氣工程的變壓器的使用的過程中都容易發(fā)生短路的情形,所以說這種故障一旦發(fā)生了就會(huì)產(chǎn)生比較嚴(yán)重的問題。加入變壓器的出口發(fā)生了短路的現(xiàn)象,那么高低導(dǎo)線的纏繞過程中能夠發(fā)生比額定電流多十倍的電流,那么就讓導(dǎo)線內(nèi)部體系聚集了較多的熱量,這樣就會(huì)發(fā)生嚴(yán)重的危險(xiǎn)。所以,一定要對(duì)出口進(jìn)行嚴(yán)格的檢查,發(fā)現(xiàn)問題馬上解決。
3.2 對(duì)于絕緣體故障方式的檢查
油田電氣工程建設(shè)電力變壓器的絕緣層體系,在系統(tǒng)的使用過程中具有著舉足輕重的地位,一般來將是起著保護(hù)的作用,特別是變壓器在正常工作和使用的時(shí)候,這種絕緣層是十分重要的,也是保障安全運(yùn)行的基礎(chǔ)條件,變壓器在運(yùn)行的過程里面是否具有較長(zhǎng)的壽命取決于絕緣層是否完好,所以說絕緣體系如果突然發(fā)生了故障那么就會(huì)對(duì)變壓器的正常工作發(fā)生了較大的影響。對(duì)于絕緣體檢查更是決定了這個(gè)電氣工程的質(zhì)量。
參考文獻(xiàn)
[1]徐培培.油田生產(chǎn)用野營(yíng)房的電氣安裝與質(zhì)量控制[J].環(huán)球市場(chǎng)信息導(dǎo)報(bào)(理論),2012(8):69-69.
[2]劉慧敏,史德明,程普,等.油田用羅茨風(fēng)機(jī)電氣控制系統(tǒng)的改進(jìn)[J].油氣田地面工程,2012,31(7):70-70.
中圖分類號(hào):TU74文獻(xiàn)標(biāo)識(shí)碼: A
1、電氣工程施工常見問題分析
隨著經(jīng)濟(jì)水平的發(fā)展和科學(xué)技術(shù)水平的提高,人們的生活質(zhì)量也在不斷的得到改善。與此同時(shí),電氣工程安裝的質(zhì)量受到人們?cè)絹碓蕉嗟年P(guān)注。先進(jìn)的施工材料、施工技術(shù)和施工設(shè)備等,都為電氣工程安裝提供了優(yōu)越的條件。就目前而言,電氣工程安裝過程依然存在很多問題,如:人員素質(zhì)、設(shè)備材料問題、避雷接地、設(shè)計(jì)圖紙問題、電纜敷設(shè)等問題。
1.1、安裝人員素質(zhì)問題
安裝人員的素質(zhì)是提高電氣安裝質(zhì)量的基礎(chǔ)。就目前來說,在電氣工程安裝領(lǐng)域中,大多數(shù)的安裝人員雖然多年從事電氣工程安裝工作,擁有較豐富的施工經(jīng)驗(yàn),但是文化素質(zhì)普遍較低,對(duì)一些理論性的專業(yè)知識(shí)和一些細(xì)節(jié)內(nèi)容掌握較弱,尤其是在日常專業(yè)知識(shí)考試、現(xiàn)場(chǎng)考問等方面明顯不足,開工資料跟不上“規(guī)范化”施工要求等。電氣安裝人員的整體文化素質(zhì)較弱,顯然這已經(jīng)成為一種普遍的現(xiàn)象。這種現(xiàn)象的存在明顯與現(xiàn)代電氣工程安裝要求嚴(yán)重不符,同時(shí),還會(huì)給工程安裝帶來嚴(yán)重的安全隱患。
1.2、設(shè)備材料問題
隨著市場(chǎng)經(jīng)濟(jì)的迅猛發(fā)展,電氣工程安裝也隨之發(fā)展。與此同時(shí),電氣工程安裝市場(chǎng)的設(shè)備材料競(jìng)爭(zhēng)越來越激烈。有些廠家采取降低產(chǎn)品質(zhì)量的方式,來贏取更高的利潤(rùn)空間,從而使得電氣安裝的質(zhì)量受到了嚴(yán)重威脅,并給電氣工程安裝帶來了極大的安全隱患,造成更大的經(jīng)濟(jì)損失。目前,常見的設(shè)備材料問題主要有:導(dǎo)線的溫度系數(shù)低、絕緣性差、熔點(diǎn)低、電阻率高;電纜絕緣電阻小、耐溫耐壓低、抗腐蝕性較差等,這些問題都會(huì)給電氣工程安裝質(zhì)量埋下不可估算的安全隱患,同時(shí)也給客戶用電和人們的生命財(cái)產(chǎn)安全帶來極大的威脅。
1.3、接地網(wǎng)問題
充分了解防雷接地裝置可能會(huì)出現(xiàn)的最大電位,及時(shí)采取相應(yīng)有效措施,是避免雷擊事故發(fā)生的關(guān)鍵。在電氣安裝過程中,常常由于安裝人員的責(zé)任心較弱,往往對(duì)圓鋼地網(wǎng)埋深不夠、連接處焊接面積不足、焊接點(diǎn)未及時(shí)上漆等,這些現(xiàn)象往往會(huì)導(dǎo)致接地極電阻值測(cè)試達(dá)不到要求,將直接影響到設(shè)備受雷擊時(shí)泄流的作用,對(duì)設(shè)備帶來致命的傷害。
1.4、設(shè)計(jì)圖紙問題
對(duì)于一些電網(wǎng)改造工程,部分設(shè)計(jì)人員責(zé)任心不強(qiáng),走過場(chǎng),設(shè)計(jì)出來的圖紙與現(xiàn)場(chǎng)嚴(yán)重不符的現(xiàn)象時(shí)有發(fā)生。設(shè)計(jì)人員在前期的設(shè)計(jì)走訪中,缺少與當(dāng)?shù)毓╇娝爱?dāng)?shù)卮逦k的溝通,沒有去深入了解當(dāng)?shù)卮迩f發(fā)展規(guī)劃,也沒有去領(lǐng)會(huì)供電所改造的本意,更沒有去了解當(dāng)?shù)氐牡匦蔚孛簿桶言O(shè)計(jì)圖畫出來,等到實(shí)際施工時(shí)才發(fā)現(xiàn),新線行與村民的房屋規(guī)劃、山地樹林、農(nóng)田莊稼等有著沖突,也與供電所改造線路目的相違背,以前的線路大部分遠(yuǎn)離交通要道,多數(shù)在半山腰上,每當(dāng)線路出現(xiàn)故障搶修時(shí)相當(dāng)麻煩,本想借線路改造機(jī)會(huì)把線行改到公路邊來,利于日后的檢查維護(hù),由于缺少一些溝通,出現(xiàn)了以上種種不利現(xiàn)象。
1.5、電纜敷設(shè)問題
在電氣安裝過程中,電纜敷設(shè)是施工要求較高的一項(xiàng)工作。在電纜敷設(shè)過程中,通常是由于安裝人員工作態(tài)度不認(rèn)真、對(duì)施工規(guī)范要求不了解以及相應(yīng)的施工管理不到位,往往會(huì)導(dǎo)致以下問題:電纜敷設(shè)后發(fā)現(xiàn)電纜長(zhǎng)度不對(duì)應(yīng)了,導(dǎo)致電纜頭制作不了;電纜頭制作過程不嚴(yán)謹(jǐn),導(dǎo)致后續(xù)加壓試驗(yàn)不合格;管口毛刺不進(jìn)行處理就直接進(jìn)行金屬管對(duì)口焊接,電纜敷設(shè)時(shí)給電纜絕緣層造成外界傷害;金屬管穿越橋架未接地或接地不牢等,這些都會(huì)給電纜運(yùn)行帶來極大的安全隱患。
2、解決辦法
2.1、提高安裝人員的專業(yè)素質(zhì)
提高電氣工程質(zhì)量的關(guān)鍵是提升安裝人員的專業(yè)素質(zhì)。施工單位在選擇電氣安裝人員時(shí),即要選擇擁有豐富經(jīng)驗(yàn),也要選擇具備相關(guān)理論知識(shí)的技能人才,才能使得整個(gè)電氣安裝隊(duì)伍的專業(yè)素質(zhì)得到提升并使其更加知識(shí)化。另外,為了避免電氣安裝質(zhì)量和事故的發(fā)生,施工人員還要在原有的知識(shí)和技術(shù)的前提下,不斷加強(qiáng)對(duì)先進(jìn)技術(shù)和先進(jìn)知識(shí)的學(xué)習(xí)培訓(xùn),對(duì)較復(fù)雜的電氣設(shè)備進(jìn)行專業(yè)的輔導(dǎo)及圖紙數(shù)據(jù)分析后方可安裝施工,以此來杜絕不必要的錯(cuò)誤發(fā)生。
2.2、加強(qiáng)圖紙?jiān)O(shè)計(jì)前的溝通協(xié)調(diào)工作
在進(jìn)行相關(guān)圖紙?jiān)O(shè)計(jì)前,相應(yīng)的設(shè)計(jì)人員應(yīng)該根據(jù)當(dāng)?shù)氐拿袂?、地形,做一個(gè)走訪調(diào)查,與當(dāng)?shù)毓╇娝按逦k進(jìn)行面對(duì)面的溝通,了解當(dāng)?shù)毓╇娝鶎?duì)新線路的一些要求及村民對(duì)本村房屋的規(guī)劃,山地樹林種植情況,農(nóng)田莊稼收割情況等做一個(gè)系統(tǒng)的了解, 對(duì)設(shè)計(jì)圖紙中存在的不利于施工的問題進(jìn)行研究,根據(jù)商討作出必要的修正,以此來避免電氣設(shè)計(jì)圖紙中與現(xiàn)場(chǎng)實(shí)際不符的現(xiàn)象發(fā)生,減少了因村民阻工帶來的窩工現(xiàn)象及因設(shè)計(jì)變更導(dǎo)致的材料增補(bǔ)而出現(xiàn)的麻煩事,加強(qiáng)溝通與協(xié)調(diào)是避免以上難題的關(guān)鍵,同時(shí)也避免不必要的經(jīng)濟(jì)損失。
2.3、臨時(shí)用電安全措施
電氣工程施工的臨時(shí)用電一定要按照《施工現(xiàn)場(chǎng)臨時(shí)用電安全技術(shù)規(guī)范》,臨時(shí)用電的方案必須要有專業(yè)的電氣專業(yè)的技術(shù)工作人員來編寫經(jīng)過負(fù)責(zé)人的審核和檢查后,才能作為現(xiàn)場(chǎng)檢查和防護(hù)的標(biāo)準(zhǔn)。在配置臨時(shí)用電系統(tǒng)時(shí)要進(jìn)行現(xiàn)場(chǎng)勘測(cè),確定電源總線合理分配電箱和線路走向。做好負(fù)荷計(jì)算導(dǎo)線的選取能構(gòu)承受電壓負(fù)荷。制定安全用電措施,一旦發(fā)生危險(xiǎn),立即采取措施。另外,臨時(shí)用電需要得到有關(guān)部門的許可,有責(zé)任意識(shí)和安全意識(shí)。
2.4、配電箱體的掩埋和安全標(biāo)注
配電箱的預(yù)埋需要根據(jù)一次到位法的要求進(jìn)行施工,配電箱體垂直,面板邊緣緊貼墻壁,配電箱體的防止要注意其功能的發(fā)揮和觀感的美觀。安全標(biāo)注是指況電箱體的安全電壓范圍要明確標(biāo)注,以防用電過高造成人員傷亡。配電箱體的負(fù)責(zé)人標(biāo)注清楚責(zé)任到人規(guī)范配電箱體的配置。
2.5、做好電纜敷設(shè)
在進(jìn)行電纜敷設(shè)時(shí)應(yīng)注意以下幾點(diǎn):1)確認(rèn)好電纜走向,選好電纜長(zhǎng)度,敷設(shè)電纜時(shí)一定要按計(jì)劃路線走,并盡量敷直,避免敷設(shè)后長(zhǎng)度不對(duì)應(yīng)的情況出現(xiàn)。2)在轉(zhuǎn)彎井,電纜必須留有足夠的弧度,避免彎度過小,電纜受擠壓,破壞電纜里面的絕緣層和保護(hù)層,因?yàn)橐坏╇娎|受到外力擠壓,絕緣性能將大大降低。3)終端頭和中間頭制作,必須是要持有專業(yè)“電力電纜”特種作業(yè)人員制作,由于不同廠家開關(guān)柜結(jié)構(gòu)也不一樣,必須按照廠家給出的圖紙去制作電纜頭,不能單憑經(jīng)驗(yàn)去制作。4)為了防止電纜損傷,穿管敷設(shè)電纜或電纜井內(nèi)敷設(shè)電纜,必須放有足夠的滑輪和牽引繩,不能用蠻力去拉扯電纜,避免電纜的保護(hù)層受到外力破壞,對(duì)電纜造成無可挽回的傷害。
2.6、安全隔離開關(guān)設(shè)置
安全隔離開關(guān)是一種用于高壓開關(guān)電器中的使用最多的一種裝置,它是電器安裝施工中最為關(guān)鍵的部分。安全隔離開關(guān)配置設(shè)置方面:①這只漏電保護(hù)器,總電箱和分配電箱至少設(shè)置兩級(jí)漏電保護(hù)器,以保證用電安全;②電箱還要設(shè)置隔離開關(guān),切斷電路時(shí),有明顯的斷開間隙,能保證其他電氣設(shè)施的安全檢修;③在電氣設(shè)備檢修時(shí),也需要一個(gè)電氣間隔,其應(yīng)該屬于明顯可見的斷開點(diǎn),能夠切實(shí)保障維護(hù)人員的人身安全。安全隔離開關(guān)操作設(shè)置方面:①安全隔離開關(guān)不能帶額定負(fù)荷或大負(fù)荷操作,不能分、合負(fù)荷電流和短路電流,但是有滅弧室的可以帶小負(fù)荷及空載線路操作。②安全隔離開關(guān)一般送電操作時(shí),先合隔離開關(guān),后合斷路器或負(fù)荷類開關(guān);斷電操作時(shí):先斷開斷路器或負(fù)荷類開關(guān)后斷開隔離開關(guān)。
2.7、開關(guān)、插座問題
當(dāng)安裝插座、開關(guān)時(shí),應(yīng)當(dāng)做好清潔工作,盒里的砂礫、泥漿都清理干凈,線盒預(yù)埋要稍微淺一點(diǎn),當(dāng)遇到必須要深的地方,應(yīng)該另外裝一個(gè)線盒。暗開關(guān)和插座的安裝要堅(jiān)固,安裝完后,檢查螺絲是否擰到位盒內(nèi)導(dǎo)線間隙一般以100~150mm為標(biāo)準(zhǔn),不能偷工減料。
2.8、避雷措施
接地、防雷措施中,經(jīng)常會(huì)出現(xiàn)接地線搭接、焊接過短捍接單面,接地電阻的設(shè)置不符合標(biāo)準(zhǔn)等問題。在設(shè)置防雷措施中要著重注意。位于建筑物頂端的避雷針要與建筑物外露的金屬連接在一起,并且跟避雷引下線連接好,避免靜電干擾。引下線的橫截面積要大于避雷針的截面,搭接處要飽和、平整。
總之,隨著我國(guó)經(jīng)濟(jì)結(jié)構(gòu)的不斷調(diào)整與轉(zhuǎn)型,各大行業(yè)都得到快速穩(wěn)健的發(fā)展。特別是在工程領(lǐng)域,隨著國(guó)家對(duì)基礎(chǔ)建設(shè)的投資加大以及施工技術(shù)、和施工管理方式的改善,電氣工程在工程行業(yè)發(fā)揮著越來越大的作用,對(duì)經(jīng)濟(jì)發(fā)展和技術(shù)進(jìn)步的貢獻(xiàn)巨大。電氣工程施工管理不僅能夠保證電氣工程的高效運(yùn)轉(zhuǎn)與工程質(zhì)量,而且還能為整體工程建設(shè)提供技術(shù)上的有力保障,能夠從根本上保障我國(guó)電氣工程行業(yè)和電氣工程建設(shè)的高效有序發(fā)展。
參考文獻(xiàn)
[1]盧文江.建筑電氣工程施工常見問題及防治策略[J].科技創(chuàng)新與應(yīng)用,2013,19:259.
【引言】:建筑電氣工程施工主要分為兩種,一種是電氣裝置的安裝,另一種是線路敷設(shè)的施工。在實(shí)際的生活中,電氣工程的施工技術(shù)得到更新,質(zhì)量有了很大程度的保證,但還是不可避免的存在一些問題,例如在技術(shù)水平、人員水平、管理水平、施工水平等多方面的客觀問題,下文將做出具體的闡述并提出相應(yīng)建議。
1.建筑電氣工程施工中的常見問題
1.1施工藝問題。
有效的控制電氣安裝過程實(shí)際上是為正常施工提供基礎(chǔ)條件,建筑電氣工程的過程控制受施工工藝的影響較大,這就對(duì)核心施工工藝提出了更高的要求。與此同時(shí),受施工條件影響而產(chǎn)生的一系列偏差都應(yīng)該考慮到,以便能夠真正做到對(duì)設(shè)備安裝情況的實(shí)時(shí)控制。
1.2電氣線路處理方面存在不妥
在進(jìn)行建筑電氣施工時(shí),電氣線路保護(hù)工作需要額外注意,如果沒有采取保護(hù)措施,很容易導(dǎo)致線路破損。目前在建筑電氣施工時(shí)就存在一些線路沒有得到保護(hù)的問題,比如說線路在建筑中穿線時(shí),施工人員為了簡(jiǎn)單化,沒有將導(dǎo)線放入到管中,而建筑中有很多棱角,稍有不注意就會(huì)使得線路受到巨大磨損,為電氣施工埋下隱患。在電氣的絲扣連接處以及在通過接線盒的時(shí)候,很多施工人員不采取正確措施,不焊跨接線或者將金屬管口焊穿,導(dǎo)致金屬管沒有正確接地,這樣就使得建筑線路不安全因素顯著增加。
1.3安裝人員水平限制。建筑電氣工程的施工過程中,應(yīng)該把安裝技術(shù)管理工作放在首要位置,并建立相應(yīng)的技術(shù)管理制度,約束施工人員的行為。定期對(duì)安裝人員進(jìn)行職業(yè)素質(zhì)和施工技能培訓(xùn),提高人員的技術(shù)水平、減少錯(cuò)誤行為,這些都將直接或間接的對(duì)施工質(zhì)量、產(chǎn)生影響。
1.4建筑電氣施工缺乏良好管理
考慮到建筑電氣施工的復(fù)雜性,在進(jìn)行建筑電氣施工時(shí),需要重視人力、物力的合理使用,而這離不開建筑電氣施工的管理工作。建筑電氣的施工質(zhì)量不僅包括施工技術(shù)的高質(zhì)量,還包括電氣材料的審核、把關(guān)。
1.5防雷接地過程中的相關(guān)問題
在建筑電氣工程的施工過程中,防雷接地對(duì)于建筑強(qiáng)弱電系統(tǒng)的運(yùn)行有著重要的意義,其中主要包括以下幾個(gè)問題:第一、在建筑強(qiáng)弱電系統(tǒng)中,往往存在著重復(fù)接地的問題。第二、有些施工人員并沒有按照相關(guān)的規(guī)章制度進(jìn)行作業(yè),從而導(dǎo)致接地裝備和引下線滿足不了建筑物的防雷要求[1]。
2.對(duì)建筑電氣施工過程中常見問題采取的對(duì)策
2.1創(chuàng)新施工工藝
科技是提高生產(chǎn)力的第一要素,只有技術(shù)能得到及時(shí)創(chuàng)新,電氣工程施工才能得到質(zhì)的發(fā)展,近些年來我國(guó)電氣工程施工質(zhì)量得到迅猛發(fā)展,也是得益于技術(shù)的發(fā)展。針對(duì)上文中的問題,個(gè)人認(rèn)為應(yīng)該要加強(qiáng)對(duì)技術(shù)的研發(fā)工作,還是以隔離器為例,就其本身來說在電路的設(shè)計(jì)方面就運(yùn)用了新技術(shù),而隨著時(shí)代的發(fā)展,在隔離器的技術(shù)革新方面又逐漸朝著隔離端子日益小型化的方向發(fā)展,這樣可以有效的縮小利用空間,此外降低內(nèi)部功耗也是目前研發(fā)的重點(diǎn)科目【2】。
2.2做好管內(nèi)穿線工作
為了確保建筑電氣線路施工時(shí)線路不受損,需要在穿線時(shí)用套管穿線,并且在穿線管的管口處安裝套管,有效的保護(hù)電氣線路的完整性。同時(shí)注意在穿線時(shí)盡量將不同的線路按照顏色進(jìn)行分類,這樣可以使得線路條理化,有利于線路連接,同時(shí),在進(jìn)行線路連接時(shí),在同一個(gè)穿管中盡量不要放入太多導(dǎo)線,可以更好的進(jìn)行以后的維護(hù)、修理等工作。
2.3提高施工人員 的技術(shù)水平
施工人員的技術(shù)水平直接決定著工程質(zhì)量的好壞。提高施工人員的技術(shù)水平會(huì)造成一種雙贏的局面。首先,施工人員自身的技術(shù)水平得到了提高,他們自身能夠得到更大的工作空間,為自己贏得更多的競(jìng)爭(zhēng)機(jī)會(huì)。其次,施工人員技術(shù)水平的提高相應(yīng)的也能夠提高工程的質(zhì)量。施工人員的技術(shù)提高后,在防雷接地,管路敷設(shè),配電箱安裝等施工難點(diǎn)處能夠更好處理意外情況的發(fā)生,使得建筑電氣工程的施工能夠安全有序的進(jìn)行。這樣的話,不僅能夠節(jié)省更多的時(shí)間,也能夠大大提高工程的質(zhì)量。
2.4加強(qiáng)建筑電氣施工管理工作
建筑電氣的設(shè)計(jì)方案是否合理直接關(guān)系到建筑電氣是否可實(shí)現(xiàn),而在建筑電氣施工過程中加強(qiáng)管理工作則關(guān)系到建筑電氣的質(zhì)量,因此,在進(jìn)行建筑電氣施工時(shí),需要重視管理工作,在建筑電氣施工時(shí)對(duì)需要重視的問題通過監(jiān)督、管理,確保施工能夠順利進(jìn)行。同時(shí)為了確保建筑電氣施工最后設(shè)計(jì)能夠符合設(shè)計(jì)的基本要求,在施工過程中,需要對(duì)施工人員做好指導(dǎo)工作,對(duì)存在的問題及時(shí)解決,以防影響到后序工作的進(jìn)行。在建筑電氣施工時(shí),特別是重要環(huán)節(jié),比如說避雷設(shè)備的安裝、線路的鋪設(shè)等,需要做到每一道工序都能滿足要求,檢驗(yàn)結(jié)果達(dá)到設(shè)計(jì)方案的要求,只有做好建筑電氣施工的管理工作,才更有利于提高建筑氣施工質(zhì)量。
2.5 采取正確的防雷接地措施
在建筑電氣工程中,防雷接地技術(shù)是重中之重。但是,現(xiàn)在很多的建筑電氣工程在這方面都做得不夠好,因此導(dǎo)致了工程的施工難以正確順利的進(jìn)行。由此可見,采取必要有效的防雷接地措施是保證工程安全穩(wěn)定完成的關(guān)鍵。所以,必須按照相應(yīng)的規(guī)范要求,嚴(yán)格采用圓鋼,而不能用其他鋼替代。另外,避雷的引下線應(yīng)做好焊接處理工作,并且搭接長(zhǎng)度完全按照相關(guān)標(biāo)準(zhǔn)執(zhí)行,即大于等于鋼筋直徑的六倍。最后就是,進(jìn)行焊接時(shí)產(chǎn)生的殘?jiān)鼞?yīng)及時(shí)清除,做到焊接處無痕,平整,均勻【3】。
結(jié)束語(yǔ)
建筑電氣施工工作是一項(xiàng)工程力度大、周期長(zhǎng)的復(fù)雜工程,確保建筑電氣施工質(zhì)量直接關(guān)系到建筑電力使用以及建筑質(zhì)量安全問題。為了確保施工質(zhì)量,在施工過程中對(duì)一些常見又關(guān)鍵的電氣問題需要采取正確措施,同時(shí)重視施工管理工作以及施工技術(shù)人員的培訓(xùn)工作,只有這樣,才會(huì)更好的提高建筑電氣施工質(zhì)量。
【參考文獻(xiàn)】:
【 abstract 】 the transformer substation construction is a systems engineering, request the parties can mutual cooperation, joining into the common coordination, supervision engineer in the construction site for the center, familiar with the construction drawings and related construction and acceptance standard, use the right monitoring means, the rapid processing project construction appears in the common problem. Based on the substation electrical engineering supervision new problems in the course as an example, this paper analyzes and discusses the causes of the problems, how well the prevention measures to avoid, and puts forward some views.
【 keywords 】 substation; Supervision; Common problem; countermeasures
中圖分類號(hào): TM63 文獻(xiàn)標(biāo)識(shí)碼:A 文章編號(hào):
1施工準(zhǔn)備階段常見問題
1.1不重視電氣施工圖會(huì)檢與設(shè)計(jì)交底
施工圖紙是監(jiān)理單位和施工單位開展工作最直接的依據(jù),圖紙中差錯(cuò)難免存在,設(shè)計(jì)交底與圖紙會(huì)檢是保證工程質(zhì)量的重要環(huán)節(jié),也是保證工程質(zhì)量的前提,更是保證工程順利施工的主要步驟,故圖紙會(huì)檢與設(shè)計(jì)交底更顯必要。目前變電站的建設(shè)從設(shè)計(jì)、施工到竣工驗(yàn)收、投產(chǎn)在時(shí)間安排上十分緊促,經(jīng)常出現(xiàn)電氣施工圖紙剛拿到還沒有認(rèn)真審查與交底,現(xiàn)場(chǎng)就已經(jīng)開始施工,出現(xiàn)這種現(xiàn)象的根源在于參建單位不重視施工圖會(huì)檢與設(shè)計(jì)交底,沒有真正理解它們的作用。
開工前工程人員審閱圖紙是十分重要的工作內(nèi)容之一,通過審閱施工圖不僅能把握工程全局,明確工程材料特點(diǎn)和設(shè)計(jì)特點(diǎn) ,而且能運(yùn)用自身的經(jīng)驗(yàn)發(fā)現(xiàn)圖紙中的疏漏,避免倉(cāng)促上陣或因過程些許失查而造成實(shí)際本不該發(fā)生的工程錯(cuò)誤和障礙。因此,針對(duì)變電站電氣專業(yè)性強(qiáng),監(jiān)理工程師必須提前進(jìn)入角色,變電站土建施工階段實(shí)時(shí)了解進(jìn)度情況,主動(dòng)與業(yè)主、設(shè)計(jì)方面聯(lián)系,掌握電氣專業(yè)出圖計(jì)劃,收到施工圖設(shè)計(jì)文件后,及時(shí)組織施工單位以及建設(shè)單位、設(shè)計(jì)單位、材料、設(shè)備供貨等相關(guān)單位進(jìn)行圖紙會(huì)檢,如果施工圖紙?jiān)陂_工前未全部到齊,可先進(jìn)行分部工程圖紙會(huì)檢,會(huì)檢后督促設(shè)計(jì)單位按時(shí)提交會(huì)檢意見。
1.2 各專業(yè)施工圖紙的相互結(jié)合深度不夠
變電站建設(shè)涉及的專業(yè)包括土建建筑與結(jié)構(gòu)、消防、給排水、通風(fēng)空調(diào)、電氣一次與二次、動(dòng)力與照明、通信系統(tǒng)、視頻與環(huán)境監(jiān)控系統(tǒng)等,專業(yè)交叉多,在施工圖設(shè)計(jì)階段,由電氣專業(yè)對(duì)土建專業(yè)提出具體技術(shù)要求,如電纜橋架安裝的固定鐵構(gòu)件預(yù)埋,電氣設(shè)備安裝基礎(chǔ)尺寸大小,屏柜安裝、電纜敷設(shè)的預(yù)留孔洞等等,這些要求應(yīng)在土建結(jié)構(gòu)施工圖中得到反映,但存在設(shè)計(jì)人員責(zé)任心不強(qiáng),本專業(yè)設(shè)計(jì)時(shí)對(duì)其他專業(yè)的要求考慮不全面,在施工圖設(shè)計(jì)階段經(jīng)常出現(xiàn)設(shè)備具體廠家還未確定等因素,導(dǎo)致后續(xù)施工過程出現(xiàn)基礎(chǔ)尺寸與設(shè)備尺寸不相符,孔洞預(yù)留不對(duì)應(yīng)等問題。
預(yù)防對(duì)策:土建工程施工圖設(shè)計(jì)出來后,電氣專業(yè)的設(shè)計(jì)人員必須認(rèn)真核對(duì)預(yù)埋件的位置與尺寸,當(dāng)設(shè)備具體廠家還未確定時(shí)必須要求在土建施工圖中標(biāo)注清楚,要求土建工程施工到該處時(shí)必須暫停待設(shè)計(jì)進(jìn)行確認(rèn)后再繼續(xù)施工,以防遺漏和發(fā)生差錯(cuò)。電氣監(jiān)理人員應(yīng)該學(xué)會(huì)看懂土建施工圖紙,了解土建施工進(jìn)度計(jì)劃和施工方法,尤其是準(zhǔn)備采用的電氣安裝方法能否和土建施工相適應(yīng),收到電氣施工圖紙后,必須對(duì)照土建施工圖紙重新核對(duì)設(shè)備基礎(chǔ)尺寸和預(yù)留孔洞位置是否正確。
1.3 土建交安裝的交接驗(yàn)收手續(xù)執(zhí)行不嚴(yán)
根據(jù)國(guó)家規(guī)范,變電站土建工程達(dá)到竣工驗(yàn)收條件時(shí)才能交安裝,但是變電站的建設(shè)周期往往是前期可研、初設(shè)、施工圖設(shè)計(jì)等占用的時(shí)間比較長(zhǎng),一旦開工建設(shè),施工階段的工期就安排得非常緊,土建工程進(jìn)行到一定階段后只能進(jìn)行局部交安,這樣一來必然導(dǎo)致交接驗(yàn)收手續(xù)執(zhí)行不到位,給后續(xù)的施工造成一定的影響。
預(yù)防對(duì)策:在施工過程中,監(jiān)理項(xiàng)目部必須把握好土建交安裝這一關(guān),當(dāng)現(xiàn)場(chǎng)具備交安條件時(shí),先與業(yè)主協(xié)調(diào)好設(shè)備具體到貨時(shí)間,向施工單位發(fā)出關(guān)于土建交安裝的監(jiān)理工作聯(lián)系單,要求土建工程的施工單位提交詳細(xì)的自檢報(bào)告和交安申請(qǐng),監(jiān)理項(xiàng)目部會(huì)同業(yè)主、設(shè)計(jì)單位、土建施工單位、電氣施工單位一起進(jìn)行中間驗(yàn)收,辦理交安手續(xù),對(duì)于不具備交安條件或驗(yàn)收不符合要求的嚴(yán)禁電氣安裝單位進(jìn)場(chǎng)施工,只有通過履行這樣的中間交安手續(xù),才可以避免后續(xù)施工中的扯皮現(xiàn)象。
2施工階段
電氣安裝工程施工階段是使工程設(shè)計(jì)意圖最終實(shí)現(xiàn)并形成工程實(shí)體的階段,也是最終形成工程產(chǎn)品質(zhì)量和工程使用價(jià)值的重要階段,因此,電氣監(jiān)理工程師必須加大對(duì)施工階段常見問題的質(zhì)量控制。
2.1電氣工程與土建工程的施工配合
在變電站土建施工中,如果土建專業(yè)只考慮本身的工作,勢(shì)必影響電氣專業(yè)的施工,而且本專業(yè)的工作也難以做好。即使在某個(gè)階段,土建專業(yè)受其電氣專業(yè)的影響不大,而且完成了任務(wù),但將給整個(gè)工程的施工帶來巨大損失,這種損失不僅限于工期上,有時(shí)會(huì)造成返工直接造成經(jīng)濟(jì)或質(zhì)量上的重大損失。所以,施工中的協(xié)調(diào)配合占有十分重要的位置。電氣安裝工程是整個(gè)變電站工程非常重要的組成部分,與其他施工項(xiàng)目必然發(fā)生多方面的聯(lián)系,土建施工質(zhì)量的好壞直接關(guān)系到電氣設(shè)備將來運(yùn)行的安全與穩(wěn)定。
2 電氣工程質(zhì)量控制的相關(guān)概念
所謂的質(zhì)量控制就是質(zhì)量管理的一部分, 它的主要目的是滿足顧客或相關(guān)法律對(duì)質(zhì)量方面的要求。施工過程是工程項(xiàng)目從圖紙上的設(shè)計(jì)轉(zhuǎn)換為實(shí)物的過程, 這個(gè)過程也是整個(gè)工程質(zhì)量的決定階段, 所以電氣工程施工質(zhì)量控制是工程項(xiàng)目質(zhì)量控制中的一個(gè)重要環(huán)節(jié)。電氣工程的建設(shè)是由多個(gè)環(huán)節(jié)完成的, 所以電氣工程質(zhì)量的控制不僅是一個(gè)從原材料的質(zhì)量控制到完成工程質(zhì)量驗(yàn)收為止的全過程、全方位的系統(tǒng)過程, 還是一個(gè)從工序質(zhì)量到分項(xiàng)工程質(zhì)量再到分部工程質(zhì)量控制的系統(tǒng)控制過程。
3 電氣工程施工管理和質(zhì)量控制中存在的一些問題
3.1 對(duì)電氣工程在工程項(xiàng)目中的作用認(rèn)識(shí)不夠
工程的施工是由多項(xiàng)工程組成的, 電氣工程施工只是其中的一項(xiàng)工程, 有些工程的施工單位對(duì)電氣工程施工質(zhì)量的控制不夠重視,對(duì)電氣工程施工的質(zhì)量要求也不嚴(yán)格,并且在電氣工程施工缺乏中缺乏相適應(yīng)的質(zhì)量監(jiān)控系統(tǒng)。所以在施工過程中會(huì)頻繁出現(xiàn)偷工減料的現(xiàn)象,存在很大的安全隱患。不僅是施工單位意識(shí)不到電氣工程施工質(zhì)量控制的重要性,建設(shè)單位對(duì)電氣工程安裝重要性的人士也不夠, 通常建設(shè)單位的電氣工程的施工會(huì)按照要求來進(jìn)行, 但是電氣工程施工對(duì)整個(gè)工程項(xiàng)目的影響卻常常被忽略。
3.2 電氣工程的施工與其他專業(yè)的協(xié)調(diào)配合不到位
在整個(gè)工程項(xiàng)目的施工過程中, 電氣工程的施工不是孤立存在的,它需要與其他人員(如土建施工人員)做好專業(yè)的協(xié)調(diào)和配合,才能夠按質(zhì)按量完成電氣工程的施工。例如,如果沒有電氣施工技術(shù)人員對(duì)混凝土澆筑、各種管線預(yù)埋等環(huán)節(jié)的現(xiàn)場(chǎng)指導(dǎo)和監(jiān)督,電氣施工就不能順利的進(jìn)行。然而在實(shí)際的電氣施工過程中,各個(gè)專業(yè)的人員配合的極其不協(xié)調(diào),對(duì)電氣工程的施工帶來了很大的不便, 甚至電氣工程無法順利開展。
3.3 電氣工程施工人員的專業(yè)素養(yǎng)不高
電氣施工人員需要是經(jīng)過專業(yè)培訓(xùn), 有著較強(qiáng)的專業(yè)素養(yǎng)和責(zé)任心的人員, 并且施工人員的素養(yǎng)的高低對(duì)電氣工程施工質(zhì)量的高低有著重要影響。但是在有些工程項(xiàng)目中,電氣工程的施工人員并不熟悉與電氣施工有關(guān)的法律法規(guī), 甚至不會(huì)審閱電氣施工的圖紙和與其相關(guān)的技術(shù)文件, 他們的施工大多并不按照正常的施工程序進(jìn)行施工, 在電氣工程施工過程中可能會(huì)出現(xiàn)一些不可彌補(bǔ)的狀況。
3.4 對(duì)電氣工程施工質(zhì)量的監(jiān)督力度不夠
在電氣施工的過程中,還要做好電氣工程的監(jiān)管工作,建立系統(tǒng)、健全的監(jiān)督系統(tǒng),保證整個(gè)施工過程的施工質(zhì)量。在電氣施工過程中, 要對(duì)開關(guān)和后插座盒的線頭、預(yù)埋管的深度、進(jìn)場(chǎng)的材料等進(jìn)行檢驗(yàn),以確保其符合質(zhì)量要求。但是,一些工程項(xiàng)目意識(shí)不到監(jiān)管的重要性, 并沒有安排專門的人員來開展監(jiān)督工作,致使一些施工人員投機(jī)取巧、鉆空子偷工減料,大大的降低了電氣工程的施工質(zhì)量。
4 電氣工程施工管理和質(zhì)量控制的有效措施
4.1 施工準(zhǔn)備階段的施工管理和質(zhì)量控制
分工協(xié)作、責(zé)任明確。在電氣工程還未開始施工之時(shí),由建設(shè)單位負(fù)責(zé)工程質(zhì)量通病防治工作,重點(diǎn)抓好建筑、電氣安裝及調(diào)試和線路工程建設(shè)過程中易發(fā)生質(zhì)量通病的關(guān)鍵環(huán)節(jié); 由設(shè)計(jì)單位負(fù)責(zé)工程建設(shè)過程中強(qiáng)制性條文的貫徹和執(zhí)行;施工單位負(fù)責(zé)標(biāo)準(zhǔn)化施工工藝的實(shí)施;監(jiān)理單位負(fù)責(zé)對(duì)工程建設(shè)全過程管理,特別是對(duì)施工中的質(zhì)量通病、強(qiáng)制性條文的貫徹和執(zhí)行、標(biāo)準(zhǔn)化施工工藝進(jìn)行管理?,F(xiàn)場(chǎng)設(shè)置標(biāo)準(zhǔn)工藝和質(zhì)量通病展板。施工方的電氣工程師以及電氣安裝的技術(shù)人員應(yīng)該對(duì)電器的施工圖紙的設(shè)計(jì)要求了然于心,這就需要電氣工程師首先詳細(xì)的閱讀、深入的研究施工圖紙,領(lǐng)會(huì)施工圖紙的設(shè)計(jì)意圖,對(duì)于不明白的地方,及時(shí)的詢問相關(guān)人員。
4.2 施工階段的施工管理和質(zhì)量控制
電氣工程的施工從工程開工到工程竣工是一個(gè)相當(dāng)長(zhǎng)的過程,現(xiàn)場(chǎng)監(jiān)理電氣工程師要充分發(fā)揮作用,盡職盡責(zé)的對(duì)整個(gè)電氣施工過程做好質(zhì)量監(jiān)督,確保每個(gè)環(huán)節(jié)的施工都符合質(zhì)量要求。施工方要嚴(yán)格按照規(guī)范化的操作程序進(jìn)行施工,質(zhì)量控制程序方案要具有規(guī)范化、符合標(biāo)準(zhǔn)、可操作性強(qiáng)的特點(diǎn)。每道工序都要經(jīng)過相關(guān)人員的簽字,然后再進(jìn)行下一個(gè)工序施工,還要做好每天施工記錄工作,為日后的排查工作做好準(zhǔn)備。
在施工過程中,由施工單位針對(duì)不同的分部、分項(xiàng)工作,編制作業(yè)指導(dǎo)書,在施工圖交底的同時(shí)一并進(jìn)行審查,未經(jīng)審查不得進(jìn)行施工。在開工前落實(shí)強(qiáng)條措施,組織施工人員觀看標(biāo)準(zhǔn)施工工藝示范光盤;在施工現(xiàn)場(chǎng)設(shè)立質(zhì)量、安全展板,嚴(yán)格按標(biāo)準(zhǔn)施工流程施工。
在施工階段要嚴(yán)把材料的質(zhì)量,實(shí)施質(zhì)量控制卡制度,材料必須是有著出廠合格證、合格的檢測(cè)報(bào)告和復(fù)測(cè)報(bào)告和建設(shè)單位和監(jiān)理單位的簽字,防止使用不合格的材料。電氣工程施工階段的質(zhì)量控制還有許多細(xì)節(jié)部分要做好質(zhì)量控制,特別是在基礎(chǔ)施工階段的質(zhì)量控制中。在基礎(chǔ)工程施工中,電氣施工單位要與土建單位相互配合做好強(qiáng)、弱電專業(yè)的進(jìn)戶電纜穿墻管和止水擋板的預(yù)埋和預(yù)留工作。這一項(xiàng)工作電氣專業(yè)應(yīng)該在做墻體防水處理之前施工并完成, 這樣可以避免電氣施工導(dǎo)致墻體發(fā)生水滲漏現(xiàn)象。在電氣施工的安裝過程中,電氣施工人員要不斷的進(jìn)行學(xué)習(xí), 不斷地提高自身的專業(yè)素養(yǎng)和技術(shù)水平, 以便在施工的過程中能夠不斷的提高電氣工程施工的質(zhì)量。
5 結(jié)語(yǔ)
總之,在對(duì)電氣施工進(jìn)行質(zhì)量管理時(shí)首先要明確設(shè)計(jì)方案,進(jìn)行質(zhì)量管理主要從提高生產(chǎn)質(zhì)量實(shí)施轉(zhuǎn)變、修改、控制、檢測(cè)、控制,并建立健全的質(zhì)量管理制度,加強(qiáng)管理人員質(zhì)量監(jiān)控問題, 在保證電氣施工工程順利進(jìn)行有著至關(guān)重要的作用。但目前我國(guó)在質(zhì)量管理這一方面還存在很多不足,大部分管理部門忽略電氣質(zhì)量, 在選取材料時(shí)未嚴(yán)格按照相關(guān)規(guī)定進(jìn)行選取,導(dǎo)致材料質(zhì)量較差影響整個(gè)施工質(zhì)量,阻礙施工進(jìn)程。
參考文獻(xiàn):
[1] 孫立春.建筑電氣施工中的質(zhì)量通病和防治措施分淺談電氣工程施工管理分析[J].黑龍江科技信息,2011.
引言
在最近幾年來,伴隨著我國(guó)工業(yè)發(fā)展速度的不斷加快,電氣工程施工也開始受到了越來越多人的關(guān)注。逐漸成為一種重要的組成部分,廣泛的存在于建筑業(yè)、制造業(yè)和化工業(yè)等產(chǎn)業(yè)中。然而,由于我國(guó)電氣施工領(lǐng)域的發(fā)展時(shí)間尚短,因此在諸多細(xì)節(jié)的設(shè)置上仍然存在著比較多的問題,無論是從業(yè)人員的綜合素質(zhì),還是整個(gè)行業(yè)的監(jiān)管體系,均需要對(duì)其展開進(jìn)一步的完善。基于此,為了能夠讓我國(guó)的電氣工程施工水平達(dá)到一個(gè)新的高度,從中找到完善電氣工程施工調(diào)試工作的有效措施。
1防雷接地施工中的問題與預(yù)防措施
1.1問題現(xiàn)象
在防雷接地的施工過程當(dāng)中,如果施工人員沒有按照要求標(biāo)準(zhǔn)來進(jìn)行焊接作業(yè),并且沒有根據(jù)設(shè)計(jì)規(guī)范來采用高質(zhì)量的鍍鋅材料,那么就極有可能導(dǎo)致防雷接地的電阻值偏高,從而當(dāng)雷雨天氣出現(xiàn)時(shí)無法達(dá)到應(yīng)有的泄流速度。除此之外,施工單位的設(shè)計(jì)人員在設(shè)置鋅鋼筋時(shí),經(jīng)常會(huì)出現(xiàn)避雷接地極測(cè)試點(diǎn)設(shè)置錯(cuò)誤的情況,為后續(xù)作業(yè)埋下安全隱患。
1.2預(yù)防措施
首先,施工人員需要做好地基接地焊接工作,在操作過程中切記不可應(yīng)付了事,而是要在完成作業(yè)以后立即運(yùn)用電阻儀來進(jìn)行電阻值測(cè)量,確保其達(dá)到設(shè)計(jì)要求后方可進(jìn)入下一環(huán)節(jié)。此外,施工人員還要嚴(yán)格控制好施工材料的質(zhì)量,用于防雷接地施工的材料需要經(jīng)過專業(yè)部門的驗(yàn)證檢查,同時(shí)還要徹底且全面的排查是否在設(shè)計(jì)中應(yīng)用了達(dá)到規(guī)范標(biāo)準(zhǔn)的鍍鋅材料。其次,施工企業(yè)管理者要進(jìn)一步加大對(duì)焊工的教育力度,確保每一位施工人員都具備上崗資格證書。由于防雷接地系統(tǒng)的施工工作主要以焊接為主,因此焊接的質(zhì)量水平才是施工工程的核心之處,施工人員需要讓焊縫位置達(dá)到均勻飽滿且無瑕疵的狀態(tài)。最后,針對(duì)在建筑物內(nèi)的設(shè)備接地操作來說,施工人員需要嚴(yán)格按照強(qiáng)制性標(biāo)準(zhǔn)來進(jìn)行作業(yè)。對(duì)于那些有特殊要求的施工項(xiàng)目應(yīng)有針對(duì)性的進(jìn)行單獨(dú)設(shè)計(jì)。
以工礦企業(yè)為例,防雷引下線需要選擇同人們較遠(yuǎn)的位置,同時(shí)要運(yùn)用鋼管或角鋼來進(jìn)行保護(hù)。需要注意的是,在運(yùn)用鋼管保護(hù)的過程中,施工人員要將鋼管的管口同防雷引下線牢固的焊接到一起,避免在雷雨天氣時(shí)管內(nèi)出現(xiàn)大量積水。
2零線的虛接、實(shí)接問題及預(yù)防措施
2.1問題現(xiàn)象
零線對(duì)于單相負(fù)載具有著不容替代的重要性,在缺少零線的情況下,單相負(fù)載根本無法正常運(yùn)作。除此之外,零線的缺少同時(shí)還有可能引發(fā)另外一種不良后果,導(dǎo)致運(yùn)作正常的單相用電設(shè)備在短時(shí)間內(nèi)冒煙、燒毀。如果在零線小干線位置進(jìn)行截?cái)?,那么不同相位中正在正常運(yùn)作的單相負(fù)載處于380V電壓下,如果絕緣性能稍差的設(shè)備就會(huì)被瞬間燒毀。
2.2預(yù)防措施
為了能夠有效提高電路零線的可靠性,施工人員可以嘗試采用雙零線方案的設(shè)計(jì),或者也可以結(jié)合自身情況在零線上增加幾路零線。此外,在對(duì)電氣設(shè)備進(jìn)行調(diào)試的過程中,施工人員更加需要對(duì)接點(diǎn)的牢固性進(jìn)行全面排查,確保電路的絕緣性能可以達(dá)到測(cè)試標(biāo)準(zhǔn)。
3電線管鋪設(shè)施工常見問題及預(yù)防措施
3.1問題現(xiàn)象
如果所采用的穿線管彎曲半徑過小,就會(huì)在使用過程中出現(xiàn)褶皺或“死彎”現(xiàn)象。在電線管鋪設(shè)的施工過程中,如果電線管的埋地與埋墻深度沒有達(dá)到應(yīng)有標(biāo)準(zhǔn),并且在預(yù)制板中的敷管交叉現(xiàn)象過于嚴(yán)重,那么勢(shì)必會(huì)對(duì)土建施工的整體質(zhì)量地帶來較大的負(fù)面影響。此外,進(jìn)出箱盒內(nèi)的交叉電線管過多,不僅會(huì)增加施工人員的理順難度,同時(shí)還極有可能導(dǎo)致多層重疊情況的出現(xiàn),在造成資源浪費(fèi)的同時(shí)無法達(dá)到應(yīng)有的施工技術(shù)要求。
3.2預(yù)防措施
首先,電線層是不應(yīng)該并排設(shè)置的,如果在施工過程不具備將它們明顯分開的條件,那么施工人員可以利用小石塊來做好間隔。此外,電線管埋墻的標(biāo)準(zhǔn)需要根據(jù)墻體內(nèi)的填充砂漿強(qiáng)度來進(jìn)行制定,盡可能的將表面距離控制在15mm以上。其次,如果電線管出現(xiàn)多層重疊情況,施工人員可以采用加厚公共走道樓板的方式來予以解決,盡可能的將電線管做好隱蔽,避免意外事故的出現(xiàn)。此外,如果塔樓每層多有6套以上的數(shù)量時(shí),施工人員可以在公共走廊的天花吊頂處下功夫,確保絕大多數(shù)的住戶都可以在吊頂?shù)木€槽處來進(jìn)行走線入戶。最后,無論是明管進(jìn)箱還是暗管進(jìn)盒,施工人員都需要保證電線管處于順直的狀態(tài)。如果管徑要比箱孔小很多,那么應(yīng)采用鉆孔器來重新開孔;如果管徑同箱孔相當(dāng),那么要盡可能的運(yùn)用原孔;如果管徑要大于箱孔,施工人員最好在原孔大小的基礎(chǔ)上進(jìn)行拓寬。
4配電箱的安裝以及配線沒有達(dá)到要求
配電箱是接受電能和分配電能的控制器,它也直接控制電力負(fù)荷。工程中的照明、動(dòng)力以及弱電負(fù)荷要正常工作,配電箱的工作性就是極其重要的了。電氣工程施工中配電箱安裝中的常見問題現(xiàn)象有:箱體與墻體之間留有一定的縫隙,箱體本身不是很平直。在靠墻角安裝的時(shí)候,箱門沒有辦法全部開啟;對(duì)于箱殼的開孔不是特別符合要求,特別是還使用了電焊或者氣焊進(jìn)行開孔,破壞了箱體的油漆保護(hù)層,而且還使得箱體的美觀性受到了破壞;另外,還有就是落地的動(dòng)力箱接地不是很明顯,導(dǎo)線截面重復(fù)接地的要求沒有達(dá)到。對(duì)其的防治措施:1)監(jiān)理方應(yīng)該對(duì)現(xiàn)場(chǎng)的配電箱進(jìn)行比對(duì)核實(shí),按照設(shè)計(jì)修改通知單逐一對(duì)照,糾正開關(guān)容量偏大或偏小的錯(cuò)誤現(xiàn)象,改正回路數(shù)不夠的錯(cuò)誤。電氣設(shè)備的上下級(jí)容量配合是很嚴(yán)格的,如果沒有符合技術(shù)要求,很可能會(huì)造成系統(tǒng)的不合理運(yùn)行,會(huì)是比較差的供電性,事故的風(fēng)險(xiǎn)會(huì)增大。2)要根據(jù)供電部門的要求,動(dòng)力箱的箱體接地導(dǎo)線要顯露得比較明顯,不能夠在箱底下焊接或者接線。
5導(dǎo)線的質(zhì)量和色標(biāo)沒有達(dá)到標(biāo)準(zhǔn)
5.1問題現(xiàn)象
多股導(dǎo)線不采用銅接頭,而是直接做成了“羊眼圈”的形狀;與開關(guān)、插座、配電箱的接線端子連接的時(shí)候,一個(gè)端子上B接了好幾根導(dǎo)線;線頭在外面,導(dǎo)線的排列不是很整齊,沒有對(duì)其進(jìn)行捆綁包扎;導(dǎo)線的三相、零線、接地保護(hù)線沒有統(tǒng)一它們的顏色,或者把它們用混淆了。施工人員沒有對(duì)導(dǎo)線的接線工藝和技術(shù)熟練掌握,另外,材料采購(gòu)員沒有按照要求備足所需各種顏色及數(shù)量的導(dǎo)線,或者是施工管理人員為了節(jié)省材料而混用導(dǎo)線材料。
5.2預(yù)防措施
首先,要求施工人員加強(qiáng)對(duì)相關(guān)規(guī)范條例的學(xué)習(xí),還要多參加技能培訓(xùn)學(xué)習(xí)工作,將綜合素質(zhì)和專業(yè)素質(zhì)有效提高。其次,在接線柱和接線端上的導(dǎo)線連接最好1 根,但是,如果根據(jù)需要,要連接兩根的話,中間則需要加上平墊片;對(duì)在接線柱和接線端上進(jìn)行連接,不允許3根以上的導(dǎo)線來實(shí)施連接。還有就是,最好是橫著編排導(dǎo)線,還要求能夠做到線路整齊劃一,剝線頭的時(shí)候應(yīng)該使得各線頭的長(zhǎng)度保持一致。
結(jié)語(yǔ)
建筑電氣安裝工程質(zhì)量的好壞,是直接影響著住宅工程質(zhì)量的,這些問題不可小看,在電氣工程施工調(diào)試中出現(xiàn)的問題,我們都得認(rèn)真思考,要防范于未然,我們要在施工前弄清工程質(zhì)量的要求,制定可行的預(yù)防措施,把質(zhì)量問題扼殺在搖籃里,不能到事后才進(jìn)行補(bǔ)救。
建筑工程中包含著許多方面,建筑電氣工程就是其中的一個(gè)重要組成部分,現(xiàn)代社會(huì)各種科學(xué)技術(shù)高速發(fā)展,建筑行業(yè)也在現(xiàn)代科技的影響下,其功能逐漸豐富,向著多元化、智能化的趨勢(shì)推進(jìn),建筑電氣工程在整個(gè)建筑施工的過程中都起著舉足輕重的作用,它性能的好壞關(guān)系到建筑物整體的安全性能,以及建筑物本身安裝的一些設(shè)施設(shè)備的功能等,它關(guān)系到人們生活的各個(gè)角落,工作、學(xué)習(xí)以至于人們的生命財(cái)產(chǎn)安全。建筑電氣工程與其他工程在技術(shù)上有著較為緊密的聯(lián)系,這對(duì)于從事建筑電氣工程監(jiān)理工作的工程師來說,有著較高的技術(shù)上的要求,這就需要監(jiān)理工程師熟悉工程的整體施工程序,從設(shè)計(jì)到具體施工,最終到達(dá)完工,都需要監(jiān)理們認(rèn)真履行自身職責(zé),下文便對(duì)建筑電氣工程監(jiān)理的工作中存在的一些常見問題給出了一些筆者自己的看法,具體內(nèi)容如下所示:
一、在建筑工程設(shè)計(jì)階段以及施工準(zhǔn)備階段常見的問題及對(duì)策
1.1.1設(shè)計(jì)階段遇到的常見問題
由于現(xiàn)代高層建筑功能逐漸向多樣化發(fā)展,工程的復(fù)雜長(zhǎng)度不斷上升,這一點(diǎn)對(duì)電氣工程施工的技術(shù)水平來說成為一種嚴(yán)峻的挑戰(zhàn),另外,建筑市場(chǎng)上的人員流動(dòng)性較強(qiáng),設(shè)計(jì)人員的工作地點(diǎn)不是十分的穩(wěn)固,大多時(shí)候,只是短時(shí)間內(nèi)的工作配合,缺乏系統(tǒng)的溝通,彼此之間的交流不能夠深入具體,最突出的就是圖紙?jiān)O(shè)計(jì)、以及結(jié)構(gòu)變動(dòng)問題,最終帶來的結(jié)果就是賠款、影響工程的施工進(jìn)度等問題。在有些建筑中還會(huì)存在地下室與地面上的建筑鋪設(shè)的管道交錯(cuò)縱橫,架設(shè)混亂的現(xiàn)象,給排水及采暖設(shè)計(jì)管路與電氣安裝管路相互打架,一些公共的煤氣管道、輸電線路等設(shè)施設(shè)計(jì)的不是十分的合理。
1.1.2施工準(zhǔn)備階段遇到的常見問題
在當(dāng)前的建筑市場(chǎng)中,大部分的建筑單位都不是總承包單位,而是由總承包商又將工程外包給了其他建筑公司,這樣的施工特點(diǎn)就是施工人員的流動(dòng)性較強(qiáng),工程的施工缺乏相應(yīng)的管理者,施工的圖紙往往會(huì)模仿某些類似的工程,不能夠充分結(jié)合實(shí)際的施工環(huán)境,施工理論有時(shí)也是照抄照搬,缺乏創(chuàng)新,且不夠具體詳細(xì)。
1.1.3控制措施
①基于設(shè)計(jì)上的問題,需要電氣工程的監(jiān)理人員必須在具體施工之前詳細(xì)的全面的了解設(shè)計(jì)圖紙的每個(gè)細(xì)節(jié),在具有本專業(yè)技能的基礎(chǔ)上,輔助學(xué)習(xí)其他專業(yè)的設(shè)計(jì)知識(shí),與最初的設(shè)計(jì)者做好溝通,對(duì)不確定之處加以標(biāo)記,以徹底的領(lǐng)會(huì)設(shè)計(jì)者的意圖。此外,從事監(jiān)理工作的工程師在工程進(jìn)入施工準(zhǔn)備階段時(shí),要對(duì)工程整體的設(shè)計(jì)圖紙進(jìn)行充分的把握,認(rèn)真詳細(xì)地審閱圖紙,對(duì)諸如圖紙中存在遺漏、標(biāo)注不明,設(shè)計(jì)失誤、平面圖與系統(tǒng)圖及其他圖紙相互矛盾等問題及時(shí)整理并記錄,以便在圖紙會(huì)審和設(shè)計(jì)交底中提出,由設(shè)計(jì)人員以會(huì)審紀(jì)要、設(shè)計(jì)變更等形式予以解決,充分保證圖紙?jiān)O(shè)計(jì)的準(zhǔn)確性。在具體施工中遇到某些疑難問題時(shí),要立即與設(shè)計(jì)部門取得聯(lián)系,同時(shí)與土建、排水等專業(yè)部門做好溝通,做到第一時(shí)間解決問題。
②對(duì)于工程外包的問題,需要監(jiān)理工程師認(rèn)真審閱承包單位給出的具體的施工方案,將審核的重點(diǎn)放在電氣工程的施工技術(shù)和防護(hù)措施上,確保工程具有相對(duì)完善的保護(hù)系統(tǒng),正確的施工步驟,以及施工方法的可行性,對(duì)于工程的管理者以及相關(guān)設(shè)計(jì)人員的專業(yè)證件的真實(shí)性也要認(rèn)真的審核,防止無證上崗、超作業(yè)范圍上崗。對(duì)于工程的重點(diǎn)部分、關(guān)鍵施工程序,要具有針對(duì)性的設(shè)計(jì)出合理的施工方案,在保證工程質(zhì)量的同時(shí)合理優(yōu)化工期。
③建筑電氣工程前期準(zhǔn)備階段出現(xiàn)的問題,要求監(jiān)理人員按照監(jiān)理實(shí)施細(xì)則中規(guī)定的內(nèi)容,全面、具體的將其內(nèi)容反映給承包單位的有關(guān)施工人員和管理人員,完成技術(shù)上的交底工作,將監(jiān)理工作涉及的主要內(nèi)容和要求傳達(dá)給每個(gè)操作者,確保工程施工能夠符合監(jiān)理實(shí)施細(xì)則中的條件,施工方案也能與具體的工程環(huán)境相適應(yīng),定期或不定期的檢查工程的施工設(shè)備,確保工程高質(zhì)量完成。
二、施工過程中常見的問題及對(duì)策
2.1.1與防火安全有關(guān)的電氣工程監(jiān)理問題
①在電氣工程的建設(shè)中,電纜線防火的施工工藝的技術(shù)要求是最高的,施工的難度也相對(duì)較大,故障大多出在接頭的位置,電纜線難以承受導(dǎo)線帶來的熱量,在敷設(shè)的過程中由于彎曲半徑長(zhǎng)度不足或者是用力過大,破壞到了起到絕緣作用的氧化鎂,此時(shí),在進(jìn)行絕緣電阻測(cè)試的同時(shí),無法發(fā)現(xiàn)此項(xiàng)問題,一旦發(fā)生火災(zāi),就會(huì)影響到滅火,造成較為嚴(yán)重的后果。
②建筑電氣工程當(dāng)進(jìn)行至中期階段時(shí),便會(huì)增加對(duì)燈光的設(shè)計(jì),但有時(shí)便會(huì)忽略對(duì)功率符合的檢驗(yàn),在回路中往往會(huì)出現(xiàn)安裝燈光的功率大于預(yù)計(jì)負(fù)荷的現(xiàn)象,當(dāng)投入使用后,有時(shí)會(huì)因?yàn)榫€路過熱,引發(fā)火災(zāi)。
2.1.2控制措施
①作為監(jiān)理工程師,應(yīng)該格外注重對(duì)施工現(xiàn)場(chǎng)的巡視與檢查,監(jiān)督施工者不按照施工技術(shù)規(guī)范和設(shè)計(jì)圖紙進(jìn)行操作的現(xiàn)象,對(duì)于違反相關(guān)規(guī)定的行為要及時(shí)以下發(fā)監(jiān)理工程師整改通知單的形式給予制止、提醒,防止施工操作上的不當(dāng)行為繼續(xù)出現(xiàn)。
②對(duì)于電氣工程中較為重要的部分,監(jiān)理人員要更加引起重視,應(yīng)對(duì)其實(shí)行特殊的監(jiān)督,例如對(duì)于高壓電纜實(shí)施耐壓測(cè)試時(shí),要重點(diǎn)測(cè)試低壓電纜、母線以及絕緣電阻等部位。
2.2.1電纜、母線的安裝質(zhì)量問題
①在豎井中安裝的電纜,有時(shí)會(huì)出現(xiàn)電纜孔不能完全密封的現(xiàn)象,用于固定電纜的支架,也存在太小,不與電纜重力相匹配的問題,電纜在住戶家中安裝后,管道的封堵處理的不好。
②室外環(huán)境下的電纜,有時(shí)會(huì)由于填埋深度過淺,受到一些外界的干擾和破壞,損壞了電纜的連通性,使電纜的質(zhì)量受到較大的影響。
③有時(shí)母線的連接處在較潮濕的環(huán)境下就被接通,這嚴(yán)重違反了操作規(guī)范,銅導(dǎo)體如果未經(jīng)搪錫,或者在已經(jīng)完成搪錫的狀態(tài)下,直接將銅導(dǎo)體與鋁導(dǎo)體連接,這樣的操作極易在使用一段時(shí)間后出現(xiàn)故障,影響使用。
2.2.2控制措施
①完全按照電氣工程施工規(guī)范規(guī)定的要求進(jìn)行施工,使電纜的敷設(shè)深度符合圖紙?jiān)O(shè)計(jì)或相關(guān)規(guī)范的規(guī)定,利用麻絲和瀝青構(gòu)成的混合物將豎井中電纜通過的洞口處封閉好,有通往地下室的電纜要做好相應(yīng)的防水封堵措施。
②監(jiān)理工程師要對(duì)母線的搭接處做好認(rèn)真的檢查,確定其是否按照操作規(guī)范進(jìn)行施工,螺栓是否擰緊,力矩是否得到有效地控制等等。
結(jié)束語(yǔ)
在建筑電氣工程實(shí)施監(jiān)理的過程中,總會(huì)出現(xiàn)這樣或那樣的問題,問題的形式是較為復(fù)雜多變的,且該工程與其他工程之間聯(lián)系又較為緊密,必然對(duì)監(jiān)理工程師們具有較強(qiáng)的技術(shù)上的要求,監(jiān)理人員不僅需要對(duì)整個(gè)電氣工程的設(shè)計(jì)、施工深入了解,還要對(duì)完工后的驗(yàn)收工作充分熟知,查閱一些其他專業(yè)的相關(guān)知識(shí),分析各因素對(duì)電氣工程的影響,對(duì)于實(shí)施監(jiān)理的過程中頻繁出現(xiàn)的問題要善于總結(jié)規(guī)律,此外,監(jiān)理人員要與現(xiàn)場(chǎng)施工人員做好充分的溝通和協(xié)調(diào),定期召開會(huì)議,完成技術(shù)交底工作,在對(duì)電氣施工過程實(shí)施監(jiān)督的同時(shí),注重驗(yàn)收工作的完成,從而杜絕常見問題的發(fā)生,提高建筑的質(zhì)量。
參考文獻(xiàn)
中圖分類號(hào):TU74 文獻(xiàn)標(biāo)識(shí)碼: A
一、建筑工程中電氣安裝工程施工常見的問題 (一)室外線路進(jìn)戶管預(yù)埋方面 主要存在進(jìn)戶管與地下室外墻的防水處理不到位;管道轉(zhuǎn)彎處采用焊接燒彎,上墻管與水平進(jìn)戶管網(wǎng)電焊駁接成90°角;管材壁厚不符合規(guī)范;預(yù)埋深度不夠,與設(shè)計(jì)線路位置偏差較大等問題。 (二)電氣主要設(shè)備及材料方面 在建筑施工中,電氣主要設(shè)備和材料方面經(jīng)常存在電纜抗腐蝕性差、耐壓低、耐溫低、以及絕緣層與線芯嚴(yán)密性差;高低壓配電箱觀感差,鋼板(塑殼)厚度不夠,幾何尺寸和耐腐蝕性達(dá)不到要求;導(dǎo)線機(jī)械性能差、熔點(diǎn)低、電阻率高、絕緣差;以及各種線管壁薄、耐折性差、強(qiáng)度差,鍍鋅層質(zhì)量不符合要求等問題。 (三)線管選材及敷設(shè)方面 主要存在偷工減料,以次充好,如減少線管壁厚,用黑鐵管替代鍍鋅管;穿管施工中管彎曲半徑過小,易于出現(xiàn)“死彎”,轉(zhuǎn)彎處未按規(guī)范設(shè)置過渡盒;管子通過結(jié)構(gòu)伸縮縫及沉降縫不設(shè)過路箱,留下不安全的隱患;管子埋墻、埋地深度不夠,預(yù)制板上敷管交叉太多,影響土建施工,同時(shí)現(xiàn)澆板內(nèi)敷管集中成排成捆影響結(jié)構(gòu)安全。 (四)建筑防雷接地設(shè)施方面 主要體現(xiàn)在避雷帶、均壓環(huán)、引下線等搭接處存在虛焊、焊瘤、夾渣及焊縫不飽滿等缺陷。此外施工采用螺紋鋼替代圓鋼作為搭接材料,且焊渣不處理,避雷帶上的焊接縫(點(diǎn))未涂刷防銹漆。
二、建筑電氣施工控制對(duì)策(一)加強(qiáng)工程驗(yàn)收力度,構(gòu)建完善的質(zhì)量保證體系要想確保工程具有較高的質(zhì)量與良好的使用功能,在工程驗(yàn)收過程中,對(duì)于與規(guī)范要求不相符的應(yīng)不予驗(yàn)收,在進(jìn)行絕緣與接地測(cè)試過程中必須根據(jù)設(shè)計(jì)要求進(jìn)行。對(duì)于竣工后的工程,具體驗(yàn)收內(nèi)容是:對(duì)下引線的連接、接地極的埋設(shè)、接地線連接、避雷網(wǎng)埋設(shè)、接地線連接等各環(huán)節(jié)進(jìn)行全面細(xì)致的檢查。另外,承建單位還應(yīng)配備專業(yè)的電氣監(jiān)督人員參與到現(xiàn)場(chǎng)的管理中,嚴(yán)格根據(jù)建筑電氣安裝施工標(biāo)準(zhǔn)要求進(jìn)行,嚴(yán)格要求施工設(shè)計(jì)。工程發(fā)包單位應(yīng)聘請(qǐng)承建資質(zhì)高的單位負(fù)責(zé)電氣工程施工。(二)對(duì)施工過程質(zhì)量進(jìn)行嚴(yán)格的監(jiān)督管理必須將質(zhì)量管理貫穿到電氣施工的全過程之中,經(jīng)常性的對(duì)整改的項(xiàng)目進(jìn)行全面的檢查,檢查的主要內(nèi)容涵蓋了原材料、安全用電、安裝部位、使用功能等各個(gè)環(huán)節(jié)階段,如發(fā)現(xiàn)問題,應(yīng)令其及時(shí)整改;著重對(duì)土建與電氣專業(yè)之間的配合、預(yù)埋與穿線工序脫節(jié)這兩項(xiàng)問題進(jìn)行檢查;將分段檢查與整體檢查有機(jī)的結(jié)合,以確保電氣施工工程具有良好的效應(yīng)。(三)防雷接地措施應(yīng)做到以下幾點(diǎn):首先,搭接焊位置處的焊縫應(yīng)飽滿、平整,以提高焊接質(zhì)量;其次,管理人員必須進(jìn)一步加強(qiáng)管理力度,嚴(yán)格檢查每道工序,與要求不相符的焊縫應(yīng)及時(shí)的進(jìn)行補(bǔ)焊,同時(shí)將覆蓋的焊渣清理,并涂抹一層防銹漆;另外,《電氣裝置安裝工程接地施工及驗(yàn)收規(guī)范》中有明確的規(guī)定,避雷引下線的連接應(yīng)采用搭接焊的方式進(jìn)行,焊接的長(zhǎng)度應(yīng)是圓鋼直徑的六倍,所以,不允許采用螺紋鋼搭接鋼筋。(四)提高建筑電氣安裝水平,增強(qiáng)認(rèn)識(shí)要想確保建筑電氣工程具有高質(zhì)量,就必須要求每位電氣施工人員必須具備上崗證書,責(zé)任心強(qiáng),電氣安裝與電氣管理人員的業(yè)務(wù)素質(zhì)必須要高,必須充分的認(rèn)識(shí)到電氣工程在建筑中具有的重要位置。
三、建筑電氣工程施工技術(shù)要點(diǎn)分析
(一)管線敷設(shè)技術(shù)
在建筑電氣工程的施工過程中,管線敷設(shè)是電氣工程的基礎(chǔ)工程之一,其中常用的管路敷設(shè)方式有金屬管敷設(shè)、PVC管敷設(shè)、線槽敷設(shè)、管架敷設(shè)等。在施工過程中由于經(jīng)常出現(xiàn)電線管管壁偏薄、管壁強(qiáng)度不夠、韌性差、電線管管口連接不嚴(yán)、管線埋藏深度不夠、電線管有凹痕等管線敷設(shè)問題,對(duì)電氣工程產(chǎn)生比較明顯的負(fù)面影響,因此,需要采取一定的方法對(duì)其進(jìn)行處理。具體措施為:①對(duì)于管線導(dǎo)管的彎曲程度要控制在規(guī)定范圍之內(nèi),不得超過行業(yè)規(guī)范明確的范圍上限;②管線在墻體內(nèi)的埋藏深度不得小于15mm,同時(shí)水泥砂漿的強(qiáng)度不得低于M10,要對(duì)電線導(dǎo)管形成足夠的保護(hù)作用;③在分線盒處的施工過程中若出現(xiàn)不同電壓回路的交叉情況時(shí),應(yīng)采用金屬隔板對(duì)其進(jìn)行隔開處理。
(二)防雷接地施工技術(shù)
建筑電氣工程的防雷工作是不可缺少的一部分,是必須實(shí)施的一項(xiàng)工程任務(wù),在防雷工程中接地體的設(shè)計(jì)是其中的重點(diǎn)也是難點(diǎn)任務(wù)之一。在建筑電氣工程的接地施工中,通常利用樁基的內(nèi)部鋼筋作為防雷設(shè)備的接地體,這樣的設(shè)計(jì)利用了工程主體框架的己有設(shè)施,具有施工便捷、投資費(fèi)用少、接地效果好的優(yōu)點(diǎn)。建筑電氣工程的防雷接地體的設(shè)計(jì)分為四個(gè)方面:①利用外圈樁基和基礎(chǔ)梁的內(nèi)鋼筋共同組成的閉合環(huán),以40mmX4mm的鍍鋅扁鋼作為連接體,使建筑的外沿敷設(shè)成閉合的、環(huán)狀的、水平的接地體;②將所有樁基與閉合環(huán)進(jìn)行連接;③若接地裝置鋼筋的直徑>10mm,利用基礎(chǔ)梁底部的兩個(gè)直徑>12mm的鋼筋當(dāng)作接地體;④基礎(chǔ)內(nèi)鋼筋作為接地體時(shí),其周圍地面的深度要>0. 5m。
(三)配電箱安裝技術(shù)
配電箱對(duì)整個(gè)電氣工程的電力負(fù)荷起到全局控制作用,配電箱的安裝具有十分重要的意義,其安裝的好壞對(duì)電氣設(shè)備的正常運(yùn)營(yíng)具有直接的影響。配電箱的安裝應(yīng)遵循以下幾點(diǎn)原則:①配電箱的安裝位置要緊靠墻體,并利用膨脹螺栓進(jìn)行固定,同時(shí)還應(yīng)注意,配電箱要與地面保持一定距離,以方面人員操作;②配電箱的開孔方向及開孔位置要準(zhǔn)確,以便導(dǎo)線在配電箱內(nèi)能順利穿過;③配電箱的導(dǎo)線與電氣的連接要緊密牢固,保證質(zhì)量。
四、電氣工程中設(shè)備調(diào)試與試運(yùn)行技術(shù) 電氣調(diào)試工作,是指在電氣設(shè)備安裝工作結(jié)束后,利用相關(guān)技術(shù),按照相關(guān)的規(guī)范與規(guī)程以及制造廠家的技術(shù)要求,進(jìn)行逐步的對(duì)各個(gè)設(shè)備調(diào)整試驗(yàn),從而得出相關(guān)技術(shù)要求在設(shè)備質(zhì)量與安裝質(zhì)量是否符合,是否能夠投入正常運(yùn)行的結(jié)論。
(一)電氣工程中調(diào)試技術(shù) 在電氣工程中,對(duì)全部的電氣設(shè)備,需要在電氣工程結(jié)束后進(jìn)行調(diào)整試驗(yàn);通電檢查所有設(shè)備的相互關(guān)系與相互作用,根據(jù)生產(chǎn)工藝的要求,對(duì)設(shè)備進(jìn)行調(diào)整使其在過度工作下與正常工況下都可以正常工作;對(duì)電氣設(shè)備進(jìn)行空載與帶負(fù)荷下的調(diào)控試驗(yàn);對(duì)于繼電保護(hù)進(jìn)行整核對(duì)定值,編寫復(fù)雜設(shè)備與裝置的調(diào)試方案,審核與校對(duì)圖紙,編寫重要設(shè)備的試驗(yàn)方案以及系統(tǒng)啟動(dòng)方案;對(duì)整套啟動(dòng)過程中的電氣設(shè)備進(jìn)行調(diào)試工作并且進(jìn)行過關(guān)運(yùn)行的技術(shù)指導(dǎo)。
(二)電氣工程調(diào)試及運(yùn)行中對(duì)技術(shù)人員的要求對(duì)于調(diào)試過程中的技術(shù)問題,作為調(diào)試人員,需要在事前掌握?qǐng)D紙資料、設(shè)備制造廠家出具的試驗(yàn)報(bào)告與相關(guān)技術(shù)資料,并且了解現(xiàn)場(chǎng)設(shè)備的布置情況與有關(guān)的電氣系統(tǒng)接線等情況,然后根據(jù)規(guī)范與規(guī)程規(guī)定,將設(shè)備的調(diào)試方案進(jìn)行制定。 相關(guān)技術(shù)人員需要有高度的責(zé)任心,對(duì)各項(xiàng)指標(biāo)需逐項(xiàng)檢查、試驗(yàn),在整個(gè)調(diào)試工作完成后,還要經(jīng)過時(shí)效考驗(yàn),穩(wěn)定可靠后,才能交付使用單位。
結(jié)語(yǔ)
在科學(xué)技術(shù)迅速發(fā)展的今天,建筑電氣施工技術(shù)在人們生活中應(yīng)用越來越廣泛,與此同時(shí),對(duì)其技術(shù)的要求也越來越高。在具體的施工過程中,我們必須嚴(yán)格按照標(biāo)準(zhǔn)來執(zhí)行每一個(gè)步驟,以確保整個(gè)建筑電氣施工的順利進(jìn)行。總之,一個(gè)優(yōu)良工程的創(chuàng)建離不開各電氣管理人員之間的技術(shù)、技能與管理經(jīng)驗(yàn)的密切配合。從準(zhǔn)備工作到施工過程中的質(zhì)量監(jiān)督,每一個(gè)環(huán)節(jié)都要嚴(yán)格把關(guān),這是促進(jìn)建筑電氣施工技術(shù)進(jìn)步的關(guān)鍵因素。
參考文獻(xiàn)
對(duì)于任何工程而言,安全質(zhì)量都最為重要、關(guān)鍵,電氣工程也不例外。電氣工程不但復(fù)雜程度相對(duì)其他工程要求更高,而且質(zhì)量要求相比其他工程更高,隨著我國(guó)經(jīng)濟(jì)快速發(fā)展以及科技水平不斷提高,人們對(duì)于電氣工程建筑質(zhì)量要求越來越嚴(yán)格。在施工過程中,相關(guān)人員不但應(yīng)當(dāng)考慮電氣工程實(shí)用性,而且應(yīng)當(dāng)考慮美觀性以及其他因素。在施工過程,應(yīng)當(dāng)采取有效安全質(zhì)量控制措施,全面提升我國(guó)電氣工程質(zhì)量,本文主要對(duì)電氣工程施工中的常見問題與安全質(zhì)量控制分析。
一、電氣工程施工當(dāng)中存在的問題分析
(一)施工現(xiàn)場(chǎng)秩序較為混亂
目前,電氣工程施工管理水平比較低,從而導(dǎo)致施工秩序較為混亂,在施工過程中,尤其是施工工作安排缺乏規(guī)劃,因此導(dǎo)致施工現(xiàn)場(chǎng)秩序特別混亂,直接影響后期施工的順利開展,施工秩序混亂,嚴(yán)重影響電氣工程現(xiàn)場(chǎng)施工效率以及施工質(zhì)量。
(二)施工人員素質(zhì)有待提升
目前,我國(guó)大部分施工單位,為了節(jié)約施工成本以及獲得更大經(jīng)濟(jì)效益,因此,會(huì)大量使用沒有豐富施工經(jīng)驗(yàn)或者不具有施工技能的農(nóng)民工,不但如此,在實(shí)際施工過程中,對(duì)于沒有經(jīng)驗(yàn)農(nóng)民工,缺乏必要施工技術(shù)培訓(xùn),嚴(yán)重影響電氣工程質(zhì)量。
(三)工程偷工減料問題
電氣工程中存在偷工減料的問題,施工單位為了節(jié)約施工成本,因此,在材料方面存在偷工減料行為。例如,實(shí)際施工過程中,原本規(guī)定使用某種優(yōu)質(zhì)材料,然而施工中使用一些便宜材料,從而導(dǎo)致工程質(zhì)量受到影響。
二、電氣工程施工安全質(zhì)量控制措施
(一)施工順序加以優(yōu)化
電氣工程施工秩序?qū)τ诠こ贪踩砸约胺€(wěn)定性具有重要作用,在施工過程中,管理人員應(yīng)當(dāng)加強(qiáng)對(duì)施工順序的重視,提前做好工作安排。并且對(duì)工作順序進(jìn)行必要優(yōu)化,避免等工現(xiàn)象出現(xiàn),從而加快施工進(jìn)度。在施工過程中,明確施工人員的任務(wù)以及操作規(guī)范,并且加強(qiáng)現(xiàn)場(chǎng)監(jiān)督。促使施工人員嚴(yán)格按照優(yōu)化之后的施工秩序進(jìn)行工作。對(duì)于工作量比較大以及規(guī)模較大的工程,可以從施工人員中挑選經(jīng)驗(yàn)比較豐富的人員做班長(zhǎng),促使監(jiān)督更為到位,從而避免現(xiàn)場(chǎng)施工混亂的問題,保障現(xiàn)場(chǎng)施工順利有序進(jìn)行。
(二)提高施工人員綜合素質(zhì)
施工人員綜合素質(zhì)對(duì)于保障工程質(zhì)量具有重要作用,施工人員素質(zhì)是決定工程質(zhì)量好壞的關(guān)鍵點(diǎn)。施工人員實(shí)際施工過程中,如果缺乏操作規(guī)范以及施工技術(shù),將會(huì)給施工造成很大壓力,一方面,施工現(xiàn)場(chǎng)難以維持秩序,施工人員素質(zhì)太低,缺乏組織紀(jì)律性,難以進(jìn)行管理,工程質(zhì)量難以保障。另一方面,施工人員專業(yè)水平不夠,部分農(nóng)民工,雖然吃苦耐勞,但是缺乏專業(yè)知識(shí)以及安全意識(shí),容易導(dǎo)致現(xiàn)場(chǎng)施工出現(xiàn)安全事故以及嚴(yán)重影響影響施工質(zhì)量。
(三)加強(qiáng)材料質(zhì)量監(jiān)督
施工材料質(zhì)量直接關(guān)系工程質(zhì)量好壞,應(yīng)當(dāng)加強(qiáng)材料采購(gòu)質(zhì)量監(jiān)督,從而避免施工偷工減料問題。首先,按照施工要求,嚴(yán)格審核施工材料,檢查材料型號(hào)、規(guī)格、質(zhì)量等,確保與施工清單符合。其次,加強(qiáng)對(duì)材料性能監(jiān)測(cè),預(yù)防不合格產(chǎn)品進(jìn)入施工現(xiàn)場(chǎng),影響工程質(zhì)量。例如,選擇管道的時(shí)候,應(yīng)當(dāng)注意管道厚度符合工程施工要求,確保管材質(zhì)量達(dá)到施工標(biāo)準(zhǔn)。最后,材料采購(gòu)?fù)瓿芍螅瑢?duì)于材料入庫(kù)應(yīng)當(dāng)做好記錄,并且明確施工材料去向,倉(cāng)庫(kù)管理人員應(yīng)當(dāng)防止偷工減料問題。
三、電氣工程施工安全控制要點(diǎn)
電氣工程施工安全控制,是工程施工完成之后一系列的驗(yàn)收以及檢查工作,保障電氣工程的安全性以及可靠性。驗(yàn)收工作主要是試運(yùn)行電氣設(shè)備,運(yùn)行設(shè)備的過程中,不但應(yīng)當(dāng)熟悉電氣設(shè)備主要功能以及特點(diǎn),而且應(yīng)當(dāng)及時(shí)記錄在當(dāng)前環(huán)境下設(shè)備運(yùn)行狀態(tài)。比如記錄環(huán)境溫度、濕度變化,并且查看溫度、濕度變化是否對(duì)設(shè)備產(chǎn)生影響。此外,做好安全措施,例如接地、防雷措施,對(duì)敏感性電氣設(shè)備做好電壓穩(wěn)定保護(hù),避免電壓變化導(dǎo)致設(shè)備損壞,后期使用中,專業(yè)人士定期對(duì)設(shè)備進(jìn)行檢查以及維護(hù),確保設(shè)備安全性以及可靠性。在配電操作柜處,應(yīng)當(dāng)標(biāo)志非操作人員操作危險(xiǎn)標(biāo)志,不允許非操作人員自行操作。
四、結(jié)語(yǔ)
綜上所述,本文主要對(duì)電氣工程施工過程中存在的問題加以分析,包括施工現(xiàn)場(chǎng)秩序較為混亂、施工人員素質(zhì)有待提升、工程偷工減料的問題,嚴(yán)重影響了電氣工程的質(zhì)量以及安全性,針對(duì)存在的問題,提出了三個(gè)相應(yīng)措施,施工順序加以優(yōu)化、提高施工人員綜合素質(zhì)、加強(qiáng)材料質(zhì)量監(jiān)督,并且提出了電氣安全控制措施,做好及時(shí)維護(hù),切實(shí)保障工程安全性以及可靠性。
參考文獻(xiàn):
[1]陳智.建筑電氣工程施工的質(zhì)量控制與安全管理分析[J].四川建材,2013,01:181+183.
[2]柴東云.電氣工程施工中的常見問題及安全質(zhì)量控制研究[J].產(chǎn)業(yè)與科技論壇,2013,04:106-107.
[3]王鍇.電氣工程施工中的常見問題及安全質(zhì)量控制淺析[J].科技資訊,2014,09:140.
[4]經(jīng)華.電氣工程施工中的常見問題及安全質(zhì)量控制研究[J].企業(yè)科技與發(fā)展,2015,17:79-80.
[5]徐冬東.A公司制藥車間空調(diào)凈化系統(tǒng)安裝工程質(zhì)量控制改進(jìn)方案研究[D].吉林大學(xué),2014.
中圖分類號(hào):TU85 文獻(xiàn)標(biāo)識(shí)碼:A 文章編號(hào):1672-3791(2011)03(c)-0140-01
對(duì)任何建筑工程來說,質(zhì)量均是其施工過程中所關(guān)注的關(guān)鍵問題,電氣工程同樣如此。伴隨著我國(guó)社會(huì)經(jīng)濟(jì)的迅猛發(fā)展,科技文化同時(shí)也在不斷進(jìn)步,大量新型電氣正在快速涌現(xiàn),在促進(jìn)建筑電氣智能化的同時(shí),也給施工人員的工作帶來了不同程度的挑戰(zhàn),人們生活水平、知識(shí)水平的提升同時(shí)也促成了其審美觀念的上升,對(duì)建筑質(zhì)量的要求也上升到了更高的層次,因此,在電氣工程施工過程中,施工人員需要綜合考慮電氣的實(shí)用性、美觀及施工質(zhì)量等因素,一般電氣施工的每一環(huán)節(jié)均會(huì)對(duì)工程施工的整體質(zhì)量造成不同程度的影響,為此,在施工過程中,必須采取必要的質(zhì)量控制措施,以保障建筑電氣工程的安全性。
1 電氣工程施工中的常見問題
1.1 存在偷工減料問題
偷工減料這一問題主要發(fā)生在施工方,其為了降低施工成本,因此在購(gòu)置施工原材料過程中蒙混。比如,在實(shí)際施工過程中,工程原本規(guī)定的是使用阻燃塑料管,但是有些電氣工程的施工方卻購(gòu)買少量非阻燃塑料管以次充好,致使工程質(zhì)量受到影響。
1.2 施工秩序比較混亂
電氣工程施工由于現(xiàn)場(chǎng)管理水平較低,導(dǎo)致施工秩序比較混亂。施工人員在工作之前缺乏一定的規(guī)劃和安排,因此有時(shí)候會(huì)出現(xiàn)施工秩序顛倒,影響到后續(xù)工作的順利開展。
1.3 施工人員的整體素質(zhì)有待提高
施工方為了節(jié)省施工成本,獲取更大利益,有時(shí)候會(huì)聘用沒有施工經(jīng)驗(yàn)或者不具備相關(guān)職業(yè)技能的農(nóng)民工。除此之外,在施工之前,也沒有針對(duì)工程的實(shí)際情況展開培訓(xùn)工作,致使電氣工程的施工過程中存在著較大的安全隱患。
2 加強(qiáng)電氣工程施工安全質(zhì)量控制的有效措施
2.1 嚴(yán)格監(jiān)督施工原料的采購(gòu)環(huán)節(jié),確保原料質(zhì)量
施工原料的質(zhì)量直接關(guān)系到電氣工程的質(zhì)量,因此加強(qiáng)采購(gòu)環(huán)節(jié)的質(zhì)量控制,避免出現(xiàn)偷工減料問題非常必要。具體實(shí)施時(shí),需要嚴(yán)格核實(shí)所用的施工材料,按照施工要求,檢查材料的規(guī)格、型號(hào)、材質(zhì)是否與施工清單上的要求相符。確定所購(gòu)買材料與施工要求相符之后,還需要對(duì)材料的相關(guān)性能進(jìn)行檢測(cè),防止不合格的產(chǎn)品進(jìn)入到施工現(xiàn)場(chǎng)。比如,在選擇鍍鋅管管壁的厚度時(shí),對(duì)于薄管說,一般其厚度需要大于1.7毫米,而厚管的管壁厚度則需要超過2.6毫米。如果所使用的是聚氯乙烯管材,根據(jù)目前電氣工程的大體施工要求,應(yīng)該使用中型以上的,并且還確保管材符合重型管以及阻燃管的相關(guān)要求。此外,完成施工原料的采購(gòu)之后,要按批入庫(kù)并進(jìn)行詳細(xì)記錄。同時(shí)建立嚴(yán)格的物品出入庫(kù)等級(jí),明確施工原料的去向,這一措施可以有效防止出現(xiàn)偷工減料問題。
2.2 對(duì)施工順序進(jìn)行優(yōu)化
電氣工程的施工秩序會(huì)對(duì)施工進(jìn)度造成較大影響,進(jìn)而影響到經(jīng)濟(jì)效益,因此在實(shí)際施工過程中,相關(guān)管理人員需要重視施工順序的重要性,提前做好安排并根據(jù)自己的工作經(jīng)驗(yàn)對(duì)施工順序進(jìn)行優(yōu)化,避免出現(xiàn)“等工”現(xiàn)象,加快施工進(jìn)度。具體實(shí)施過程中,現(xiàn)場(chǎng)的施工管理人員應(yīng)該將每天的施工任務(wù),明確下達(dá)給相關(guān)工作人員,確保每個(gè)人都明確自己的任務(wù)以及相關(guān)的規(guī)范和要求。之后還應(yīng)該加強(qiáng)施工現(xiàn)場(chǎng)的監(jiān)督,讓相關(guān)人員嚴(yán)格按照優(yōu)化后的施工順序展開工作,如果施工的規(guī)模較大,管理人員還可以在負(fù)責(zé)不同施工任務(wù)的工作人員中挑選一個(gè)經(jīng)驗(yàn)比較豐富的作為組長(zhǎng),協(xié)助自己開展監(jiān)督工作。這樣的做法實(shí)現(xiàn)了分工的細(xì)化,讓監(jiān)督更加到位,混亂施工的情況可以得到有效避免,確?,F(xiàn)場(chǎng)施工的有序進(jìn)行。
2.3 加強(qiáng)施工人員的綜合素質(zhì)建設(shè)
不管監(jiān)督工作在電氣工程的質(zhì)量控制過程中發(fā)揮著多么重要的作用,基層施工人員始終才是決定工程質(zhì)量的關(guān)鍵所在。如果基層施工人員在實(shí)際施工過程中忽視操作規(guī)范,就會(huì)給監(jiān)督工作帶來很大的難度與壓力,施工現(xiàn)場(chǎng)也會(huì)變得混亂,難以管理。因此,在加強(qiáng)電氣工程施工質(zhì)量控制過程中,加強(qiáng)施工人員的綜合素質(zhì)建設(shè)也是不可忽視的一個(gè)環(huán)節(jié)。在施工之前,應(yīng)該對(duì)工作人員進(jìn)行安全培訓(xùn),讓他們意識(shí)到不規(guī)范施工的危害以及可能出現(xiàn)的危險(xiǎn),明確遵守相關(guān)規(guī)章制度的重要性,提高安全意識(shí),進(jìn)而在工作過程中時(shí)刻留意安全問題并按照施工規(guī)范開展工作。另外,除了安全培訓(xùn)之外,相應(yīng)的技能培訓(xùn)也非常必要。施工人員的施工技術(shù)水平得到提高之后,不僅工程質(zhì)量有了保障,同時(shí)也可以有效降低施工過程中由于技術(shù)原因所導(dǎo)致的安全事故,大幅提升施工安全。
3 結(jié)語(yǔ)
綜上所述,基于對(duì)電氣工程施工過程中常見問題的考慮,為規(guī)避在電氣安裝、線路敷設(shè)、管道設(shè)置、材料選擇等程序中出現(xiàn)的問題,需采取獨(dú)具針對(duì)性的質(zhì)控措施,首先,采購(gòu)原料的時(shí),必須對(duì)納入安裝的材料進(jìn)行質(zhì)量檢測(cè),確保選用的材料能夠最大限度地迎合施工要求。其次,對(duì)施工順序進(jìn)行優(yōu)化,提前做好安排并根據(jù)自己的工作經(jīng)驗(yàn)對(duì)施工順序進(jìn)行優(yōu)化,避免出現(xiàn)“等工”現(xiàn)象,加快施工進(jìn)度。最后,加強(qiáng)施工人員的綜合素質(zhì)建設(shè),強(qiáng)化施工安全意識(shí),提高施工人員的技能。這一措施不僅讓工程質(zhì)量有了保障,同時(shí)也可以有效降低施工過程中由于技術(shù)原因所導(dǎo)致的安全事故,大幅提升施工安全,進(jìn)而實(shí)現(xiàn)提升電氣工程施工質(zhì)量與安全性的目標(biāo)。
參考文獻(xiàn)
[1] 柴東云.電氣工程施工中的常見問題及安全質(zhì)量控制研究[J].產(chǎn)業(yè)與科技論壇,2013(4):106-107.